SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Ideal Heating
H6Ideal Heating · HP290

H6 on an Ideal Heating HP290: Fan Error

Short answer

On an Ideal Heating heat pump, H6 means: Fan Error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Fan Error.

Part involved: outdoor fan motor.

Likely causes:

  • Fan wiring to inverter damaged/incorrectly connected; fan motor winding fault; inverter.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Note the code or fault message shown on the controller/Halo and when it appeared; check the heat pump's isolator and consumer-unit breaker are on. Check the outdoor unit is not blocked by snow, ice, leaves or stored items and that air can flow freely around it.

What the engineer will check

  • WARNING: isolate 10 min. Check fan wiring; measure fan terminal resistances (Red-White, Red-Black, White-Black >10 ohm); replace fan or inverter.

Who to ask for: Heat pump engineer competent with R290 (A3, highly flammable); refrigerant-circuit work requires Cat I/II F-gas plus City & Guilds 6187-21 or equivalent (I&M p.93 warning).

Certification: F-gas Cat I/II + C&G 6187-21 (R290) for refrigerant work; electrical work by competent person.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026