SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Ideal Heating
LED-62Ideal Heating · Logic Air

LED-62 on an Ideal Heating Logic Air: Outdoor unit main PCB error / communication error in outdoor unit

Short answer

On an Ideal Heating heat pump, LED-62 means: Outdoor unit main PCB error / communication error in outdoor unit. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Outdoor unit main PCB error / communication error in outdoor unit.

Part involved: outdoor main PCB (EEPROM).

Likely causes:

  • 1. External cause (noise, momentary open, voltage drop) 2. Main PCB failure (EEPROM access failed).

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Note the code or fault message shown on the controller/Halo and when it appeared; check the heat pump's isolator and consumer-unit breaker are on. If the fault clears after the installer-approved restart via the controller and does not return, note it for the next service; if it returns, call an engineer. Check whether lights or other appliances are also affected (possible supply problem) and whether any breaker/RCD has tripped - do not reset repeatedly.

What the engineer will check

  • Reset power; check for voltage drops/momentary open/earthing and nearby cables; replace main PCB.

Who to ask for: Heat pump engineer; casing removal only by persons competent with R32 (A2L); refrigerant-circuit work requires Cat I/II F-gas certification (I&M p.75 warning).

Certification: F-gas Cat I/II for refrigerant work; electrical work by competent person.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026