P4Ideal Heating · HP290

P4 on an Ideal Heating HP290: Compressor Discharge Temperature High

Short answer

On an Ideal Heating heat pump, P4 means: Compressor Discharge Temperature High. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Compressor Discharge Temperature High.

Part involved: discharge temperature.

Likely causes:

  • Discharge thermistor Tp out of calibration (table of values e.g. 25C = 58 kOhm); flow/return thermistors not installed correctly; incorrect discharge pressure P1 (Table 24); low refrigerant charge; outdoor PCB.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Note the code or fault message shown on the controller/Halo and when it appeared; check the heat pump's isolator and consumer-unit breaker are on.

What the engineer will check

  • Check Tp resistance vs table; check Tw_out/Tw_in installation; compare P1 to Table 24; leak test/recharge; replace outdoor PCB or thermistor.

Who to ask for: Heat pump engineer competent with R290 (A3, highly flammable); refrigerant-circuit work requires Cat I/II F-gas plus City & Guilds 6187-21 or equivalent (I&M p.93 warning).

Certification: F-gas Cat I/II + C&G 6187-21 (R290) for refrigerant work; electrical work by competent person.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026