LED-78 on an Ideal Heating Logic Air: Electric expansion valve sensor error

Short answer

On an Ideal Heating heat pump, LED-78 means: Electric expansion valve sensor error. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Electric expansion valve sensor error.

Part involved: expansion valve temperature thermistor.

When it shows: Thermistor short or open detected.

Likely causes:

  • 1. Connector connection failure/open 2. Thermistor failure 3. PCB failure (main PCB).

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Note the code or fault message shown on the controller/Halo and when it appeared; check the heat pump's isolator and consumer-unit breaker are on.

What the engineer will check

  • Check connector and cable continuity; disconnect thermistor and check characteristic (Service Parts Information 5); check PCB reference voltage Main PCB PA1:4-6 = 5 V; replace thermistor or PCB.

Who to ask for: Heat pump engineer; casing removal only by persons competent with R32 (A2L); refrigerant-circuit work requires Cat I/II F-gas certification (I&M p.75 warning).

Certification: F-gas Cat I/II for refrigerant work; electrical work by competent person.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026