LED-65 on an Ideal Heating Logic Air: IPM error

Short answer

On an Ideal Heating heat pump, LED-65 means: IPM error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: IPM error.

Part involved: IPM on outdoor inverter PCB.

When it shows: Signal from FO terminal of IPM is L (0 V) while compressor stopped.

Likely causes:

  • Outdoor unit inverter PCB failure.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Note the code or fault message shown on the controller/Halo and when it appeared; check the heat pump's isolator and consumer-unit breaker are on.

What the engineer will check

  • Replace outdoor inverter PCB.

Who to ask for: Heat pump engineer; casing removal only by persons competent with R32 (A2L); refrigerant-circuit work requires Cat I/II F-gas certification (I&M p.75 warning).

Certification: F-gas Cat I/II for refrigerant work; electrical work by competent person.

Sources

A code explains what the controller detected, not a confirmed root cause.