P3 on an Ideal Heating HP290: Overcurrent Protection Error

Short answer

On an Ideal Heating heat pump, P3 means: Overcurrent Protection Error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Overcurrent Protection Error.

Part involved: compressor, inverter.

Likely causes:

  • Supply voltage outside 207-253 V AC; inverter defective; compressor U/V/W wiring incorrect; compressor windings (<10 ohm) or mechanical failure; associated no-water-flow (E0/E8); HP switch pipe/filter blockage; EEV fault.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: Reset lockout (p.108).

What you can check

  • Note the code or fault message shown on the controller/Halo and when it appeared; check the heat pump's isolator and consumer-unit breaker are on. Check whether lights or other appliances are also affected (possible supply problem) and whether any breaker/RCD has tripped - do not reset repeatedly.

What the engineer will check

  • Check supply voltage; test inverter; check compressor wiring and winding resistances; check compressor for seizure/wear; check EEV; replace inverter or compressor.

Who to ask for: Heat pump engineer competent with R290 (A3, highly flammable); refrigerant-circuit work requires Cat I/II F-gas plus City & Guilds 6187-21 or equivalent (I&M p.93 warning).

Certification: F-gas Cat I/II + C&G 6187-21 (R290) for refrigerant work; electrical work by competent person.

Sources

A code explains what the controller detected, not a confirmed root cause.