H0Ideal Heating · HP290

H0 on an Ideal Heating HP290: No connection Outdoor PCB to Indoor PCB

Short answer

On an Ideal Heating heat pump, H0 means: No connection Outdoor PCB to Indoor PCB. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: No connection Outdoor PCB to Indoor PCB.

Part involved: outdoor-indoor comms cable.

Likely causes:

  • Three-way comms wiring outdoor PCB to indoor control box, or control box to indoor PCB, incorrect (T1-T1, T2-T2, X/HA-X/HA, X/HB-X/HB); indoor PCB or outdoor PCB faulty.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Note the code or fault message shown on the controller/Halo and when it appeared; check the heat pump's isolator and consumer-unit breaker are on. If the fault clears after the installer-approved restart via the controller and does not return, note it for the next service; if it returns, call an engineer.

What the engineer will check

  • Check comms wiring terminations; replace indoor PCB then outdoor PCB.

Who to ask for: Heat pump engineer competent with R290 (A3, highly flammable); refrigerant-circuit work requires Cat I/II F-gas plus City & Guilds 6187-21 or equivalent (I&M p.93 warning).

Certification: F-gas Cat I/II + C&G 6187-21 (R290) for refrigerant work; electrical work by competent person.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026