Pd on an Ideal Heating HP290: Condensing Temperature High

Short answer

On an Ideal Heating heat pump, Pd means: Condensing Temperature High. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Condensing Temperature High.

Part involved: condensing pressure/temperature.

Likely causes:

  • Pressure sensor reading (P1 = P2); snow/ice on outdoor unit; blocked/dirty air HX; insufficient clearance; fan fault; EEV fault/wiring; refrigerant charge.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Note the code or fault message shown on the controller/Halo and when it appeared; check the heat pump's isolator and consumer-unit breaker are on. Check the outdoor unit is not blocked by snow, ice, leaves or stored items and that air can flow freely around it.

What the engineer will check

  • As flowchart 9.1.31: compare pressures, check airflow, fan, EEV, recharge; replace outdoor PCB/low pressure sensor.

Who to ask for: Heat pump engineer competent with R290 (A3, highly flammable); refrigerant-circuit work requires Cat I/II F-gas plus City & Guilds 6187-21 or equivalent (I&M p.93 warning).

Certification: F-gas Cat I/II + C&G 6187-21 (R290) for refrigerant work; electrical work by competent person.

Sources

A code explains what the controller detected, not a confirmed root cause.