P1 on an Ideal Heating HP290: High Pressure Switch Operated

Short answer

On an Ideal Heating heat pump, P1 means: High Pressure Switch Operated. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: High Pressure Switch Operated.

Part involved: high pressure switch.

Likely causes:

  • Often secondary to no water flow (E8/E0); HP switch wiring to inverter disconnected; refrigerant pressures >3.5 MPa; blocked/damaged pipes or filter to HP switch; EEV not operating; inverter PCB.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: Lockout reset required (p.107).

What you can check

  • Note the code or fault message shown on the controller/Halo and when it appeared; check the heat pump's isolator and consumer-unit breaker are on. Read the heating system pressure gauge (the HP290 manual cites 1-1.5 bar) and report it; check the filling loop is closed.

What the engineer will check

  • If occurred with E8/E0 follow 9.1.2; check HP switch wiring; check P1/P2 pressures; check pipes/filter; reset lockout and check EEV; replace HP switch or inverter PCB.

Who to ask for: Heat pump engineer competent with R290 (A3, highly flammable); refrigerant-circuit work requires Cat I/II F-gas plus City & Guilds 6187-21 or equivalent (I&M p.93 warning).

Certification: F-gas Cat I/II + C&G 6187-21 (R290) for refrigerant work; electrical work by competent person.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026