Heat pumps · Error codes · Ideal Heating
H2Ideal Heating · HP290

H2 on an Ideal Heating HP290: Plate Heat Exchanger Outlet Refrigerant Thermistor (T2) Error

Short answer

On an Ideal Heating heat pump, H2 means: Plate Heat Exchanger Outlet Refrigerant Thermistor (T2) Error. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Plate Heat Exchanger Outlet Refrigerant Thermistor (T2) Error.

Part involved: T2 thermistor.

Likely causes:

  • T2 not connected to outdoor PCB; thermistor outside 30-500 kOhm; outdoor PCB.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

What you can check

  • Note the code or fault message shown on the controller/Halo and when it appeared; check the heat pump's isolator and consumer-unit breaker are on.

What the engineer will check

  • Check connection; measure 30-500 kOhm; replace thermistor or outdoor PCB.

Who to ask for: Heat pump engineer competent with R290 (A3, highly flammable); refrigerant-circuit work requires Cat I/II F-gas plus City & Guilds 6187-21 or equivalent (I&M p.93 warning).

Certification: F-gas Cat I/II + C&G 6187-21 (R290) for refrigerant work; electrical work by competent person.

Sources

A code explains what the controller detected, not a confirmed root cause.