Haier heat pump error codes

Haier · A niche brand in the UK. 191 codes across 4 product families, each taken from the manufacturer’s manuals. Haier technical support ↗

Find a Haier engineer →191 codes · reviewed 23 September 2026

Filter by product family

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

191 codes

CodeMeaningStops?Homeowner check?
1
In water temp.sensor (Twi) failure
PartlyYes
2
Out water temp.sensor (Two) failure
PartlyYes
3
In refrigerant temp.sensor (Thi) failure
PartlyYes
4
Out refrigerant temp.sensor (Tho) failure
PartlyYes
5
EEPROM failure
Not statedYes
6
Communication failure with outdoor unit
Not statedYes
7
Communication fault with wired controller
Not statedYes
8
WS abnormal (water flow switch)
Not statedYes
10
Flow rate too low failure
PartlyYes
11
IO PCB communication failure
Not statedYes
12
HU zone2 behind water mixing valve temp.sensor failure
PartlyYes
14
low pressure abnormal
YesYes
15
Antifreeze fault
Not statedYes
16
Heat exchange unit HU in/out water temp. too high
Not statedYes
17
HU zone1 room temp.sensor failure
PartlyYes
18
HU zone2 room temp.sensor failure
PartlyYes
20
Defrosting temp.sensor (Te) failure
PartlyYes
21
Ambient temp.sensor (Ta) failure
PartlyYes
22
Suction temp.sensor (Ts) failure
PartlyYes
23
Discharging temp.sensor (Td) failure
PartlyYes
26
Communication failure with indoor
Not statedYes
28
High pressure sensor failure
PartlyYes
29
Low pressure sensor failure
PartlyYes
30
High pressure switch HPS failure
YesYes
33
Outdoor EEPROM failure
Not statedYes
34
Discharging temp. too high protection (Td)
Not statedYes
35
4-way valve reversing failure
YesYes
38
High pressure too low protection (Pd)
YesYes
39
Low pressure too low (Ps) / compression ratio too high protection
YesYes
40
High pressure too high protection (Pd)
YesYes
43
Discharging temp. too high protection (Td)
Not statedYes
46
Discharging communication fault with IGBT Power Module
Not statedYes
71
DC FAN failure
YesYes
75
High-low differential pressure too small / no differential pressure
YesYes
78
Too little refrigerant
YesYes
81
Radiator of transducer temp too high
YesYes
82
Compressor current protection
YesYes
83
Outdoor unit model BM setting error
Not statedYes
87
Defrosting with too low water temperature
Not statedYes
110
Module hardware excess current
YesYes
111
Compressor out of step
YesYes
112
Radiator of transducer temp too high
YesYes
113
Transducer overload
YesYes
114
Voltage too low of DC bus line
YesYes
115
Voltage too high of DC bus line
YesYes
116
Communication abnormal between transducer and control PCB
Not statedYes
117
Software excess current
YesYes
118
Compressor startup failure
YesYes
119
Current detecting circuit abnormal of transducer
YesYes
120
Module power supply abnormal
YesYes
121
Power supply of inverter board is abnormal
YesYes
122
Radiator temp. sensor abnormal
PartlyYes
555.1
Outer circumstance temp. Ta>27°C heating standby
PartlyYes
555.3
Outer circumstance temp. Ta>54°C or Ta<-10°C, refrigeration (cooling) standby
PartlyYes
555.4
Oil temp. fails to meet the condition of system start
PartlyYes
555.5
Outdoor unit mode does not match indoor unit mode (outdoor unit set to cooling-only or heating-only, conflicting with indoor unit mode) - standby
PartlyYes
E01
HU Water Inlet Temperature Sensor Abnormality
PartlyYes
E2
Over-temperature protection of heating outlet / Low temperature protection of cooling outlet
Not statedYes
E02
HU Water Outlet Temperature Sensor Two / Tout2 Abnormality
PartlyYes
E3
Water tank temperature sensor failure
PartlyYes
E03
HU Liquid Pipe Temperature Sensor Abnormality
PartlyYes
E4
Ambient temperature sensor failure
PartlyYes
E04
HU Gas Pipe Temperature Sensor Abnormality
PartlyYes
E5
Defrosting temperature sensor failure
PartlyYes
E05
EEPROM Abnormality
Not statedYes
E6
Exhaust temperature sensor failure
PartlyYes
E06
Communication Error between Outdoor Unit and Indoor Unit
Not statedYes
E7
Wire controller communication failure
Not statedYes
E07
Communication Error between Remote Wired Controller and Indoor Unit
Not statedYes
E8
High pressure switch protection, high pressure protection
YesYes
E08
Flow Switch Abnormality / Low Water Flow
Not statedYes
E9
Protection over ambient temperature range
Not statedYes
E09
Indoor Unit Address Duplication Abnormality
Not statedYes
E10
DHW Tank Temperature Sensor Abnormality
PartlyYes
E11
I/O PCB Communication Abnormality
Not statedYes
E12
HU ZONE2 Water Mixing Valve Temperature Sensor Abnormality
PartlyYes
E13
Water Leakage (reserved)
Not statedYes
E14
Low Pressure Switch Abnormality (reserved)
YesYes
E15
Anti-freeze Abnormality
Not statedYes
E16
HU Water Inlet/Outlet Temperature Over High
Not statedYes
E17
HU ZONE1 Ambient Temperature Sensor Abnormality
PartlyYes
E18
HU ZONE2 Ambient Temperature Sensor Abnormality
PartlyYes
E19
Pool Mixing Valve Water Outlet/Pool Water Temperature Sensor
PartlyYes
E20
Outdoor Unit Abnormality
Not statedYes
E20-0
Outdoor Condenser Defrosting Coil Temperature Sensor Te1 Abnormality
PartlyYes
E20-1
Outdoor Condenser Defrosting Coil Temperature Sensor Te2 Abnormality
PartlyYes
E21
Outdoor Ambient Temperature Sensor Abnormality
PartlyYes
E22
Outdoor Compressor Suction Temperature Sensor Abnormality
PartlyYes
E23
Compressor Discharge Temperature Sensor Abnormality
PartlyYes
E24
Compressor Oil Temperature Sensor Toil Abnormality
PartlyYes
E27
Oil Temperature Over High Protection (Toil)
YesYes
E28
Compressor Discharge Pressure Sensor Abnormality
PartlyYes
E29
Compressor Suction Pressure Sensor Abnormality
PartlyYes
E30
High Pressure Switch HPS Abnormality
YesYes
E32-0
Outdoor Subcooling Coil Outlet Temperature Sensor Abnormality
PartlyYes
E32-1
Outdoor Liquid Pipe Subcooling Temperature Sensor Abnormality
PartlyYes
E33
Outdoor Unit PCB EEPROM Abnormality
Not statedYes
E34
Compressor Discharge Temperature Over High Protection (Td)
YesYes
E35
Four Way Valve Reversing Abnormality
YesYes
E36
Oil Temperature Over Low Protection (Toil)
YesYes
E38
High Pressure Over Low Protection
YesYes
E39-0
Low Pressure Over Low Protection
YesYes
E39-1
Compression Ratio Over High Protection
YesYes
E40
High Pressure Over High Protection
YesYes
E43
Compressor Discharge Temperature Sensor Over Low Protection
YesYes
E46
Communication Error with Driver PCB
Not statedYes
E49
Low Pressure Switch Abnormality
YesYes
E51-0
LEVa Overcurrent Protection
YesYes
E51-2
LEVb Overcurrent Protection
YesYes
E52-0
LEVa Disconnection Abnormality
YesYes
E52-2
LEVb Disconnection Abnormality
YesYes
E53
CT Current Over Low or Current Sensor Abnormality
PartlyYes
E54
Communication Error with Subcooling Module
Not statedYes
E57
Communication Error between Subcooling Module and Main PCB (sent by Subcooling Module)
Not statedYes
E58
Subcooling Module Tc1 Temperature Sensor Error (sent by Subcooling Module)
PartlyYes
E59
Subcooling Module Tc2 Temperature Sensor Error (sent by Subcooling Module)
PartlyYes
E60
Subcooling Module(sent by Subcooling Module)
YesYes
E61
Subcooling Module(sent by Subcooling Module)
YesYes
E62
Subcooling Module(sent by Subcooling Module)
YesYes
E63
Subcooling Module Dip Switch Error
Not statedYes
E64
CT Current Over High
YesYes
E65
Electrical Control Box Temperature Sensor(Tb) Abnormality
PartlyYes
E68
Communication Error with DHW I/O PCB
Not statedYes
E69
DHW I/O PCB Tank Temperature Abnormality
Not statedYes
E70
DHW I/O PCB Other Abnormalities
Not statedYes
E71-0
Upper DC Fan Motor Abnormality
YesYes
E71-1
Lower DC Fan Motor Abnormality
YesYes
E74
System Emergency Stop Abnormality
Not statedYes
E81
Compressor Driver PCB Temperature Over High Protection
YesYes
E82
Compressor Current Protection
YesYes
E83
Incorrect Outdoor Unit Dip Switch Setting
Not statedYes
E87
Defrosting with Over Low Water Temperature
Not statedYes
E110
Compressor Hardware Overcurrent
YesYes
E111
Compressor Loss of Synchronism
YesYes
E111-4
Fan Motor Loss of Synchronism
YesYes
E112
Compressor Driver PCB Heat Sink Temperature Over High
YesYes
E112-4
Fan Motor Driver PCB Heat Sink Temperature Over High
YesYes
E114
The input power supply voltage of the inverter is abnormal
YesYes
E116
Communication Error between Compressor Driver PCB and Main PCB
Not statedYes
E117
Compressor Software Overcurrent
YesYes
E117-4
Fan Motor Software Overcurrent
YesYes
E118
Compressor Start-up Abnormality
YesYes
E119
Compressor Driver PCB Current Detect Circuit Abnormality
YesYes
E121
Compressor Control Board Power Supply Abnormality
YesYes
E122
Compressor Driver PCB Heat Sink Temperature Sensor Abnormality
PartlyYes
E124
Compressor Driver PCB Three-Phase Power Supply Abnormality
YesYes
EA
Control board memory chip failure
Not statedYes
Eb
Inlet temperature sensor failure
PartlyYes
EC
Module communication failure (no communication between the main board in case of multi-connection)
Not statedYes
Ed
Suction temperature sensor failure
PartlyYes
EF
Condenser (coil) temperature sensor failure
PartlyYes
F0
WiFi module configuration failure
YesYes
F1
4-way valve reversal failure
YesYes
F3
Over-temperature protection of compressor exhaust
YesYes
F5
High temperature of outdoor coil outlet (defrosting) temperature sensor
PartlyYes
F6
Compressor overcurrent protection
YesYes
F7
System fluoride deficiency protection (refrigerant shortage)
YesYes
F9
Low pressure switch protection / low pressure protection
YesYes
H1
Refrigerant gas pipe temperature sensor failure
PartlyYes
H2
Liquid pipe temperature sensor failure
PartlyYes
H4
Start-up failure and loss of synchronism
YesYes
H5
Total backwater (return water) failure
Not statedYes
H6
Total outlet water failure
Not statedYes
L0
Antifreeze protection
Not statedYes
L3
Outlet temperature sensor failure
PartlyYes
L4
Economizer inlet temperature sensor failure
PartlyYes
L5
Economizer outlet temperature sensor failure
PartlyYes
L6
Fan 2 feedback failure
YesYes
L7
Fan 1 feedback failure
YesYes
L8
Inverter circulating water pump failure
Not statedYes
LA
Flow switch failure
Not statedYes
LC
Antifreeze protection abnormal
Not statedYes
LE
Over-temperature difference protection of inlet and outlet
Not statedYes
LF
Three-phase electric abnormal protection
YesYes
P1
Output short-circuit protection or output instantaneous overcurrent
YesYes
P3
Over-temperature protection of IPM module radiator
YesYes
P4
Output overload, overcurrent, or three-phase imbalance
YesYes
P5
DC bus under-voltage protection
YesYes
P6
DC bus over-voltage protection
YesYes
P7
No communication of driver
Not statedYes
P8
Driver current and voltage sampling circuit failure
YesYes
PA
AC input undervoltage, open phase protection, input power abnormal or compressor reversal
YesYes
PB
Loss of synchronism detection (ID number mismatch)
YesYes
PC
Radiator sensor failure
PartlyYes
PD
Driver input overcurrent
YesYes
PF
Input instantaneous overcurrent or short circuit protection
YesYes
U2
Low pressure sensor failure
PartlyYes
U5
High pressure sensor failure
PartlyYes
UA
Discharge superheat protection
YesYes
UE
Outlet 2 temperature sensor failure
PartlyYes
UF
Mixed water temperature sensor fault
PartlyYes