E08Haier · Super Aqua R290 Hydro Split / Hydro All-in-One (AW..HUGHA/HVGHA)

E08 on a Haier Super Aqua R290 Hydro Split / Hydro All-in-One: Flow Switch Abnormality / Low Water Flow

Short answer

On a Haier heat pump, E08 means: Flow Switch Abnormality / Low Water Flow. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Flow Switch Abnormality / Low Water Flow.

Part involved: water flow switch/pump, water temperature.

When it shows: There's no water flow signal after the water pump operating for 120s (flow switch off or water flow is lower than the set value). Flow switch or water flow keeps normal for 5 minutes, the error is resolved. If it occurs 3 times in an hour, confirm the failure.

Is it safe?

Does the heat pump stop?Not stated
SeveritySafety lockout
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: yes (until locked).

Manual reset: Confirmed/locked after 3 occurrences in an hour; engineer reset after the cause is fixed.

What you can check

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the heating system pressure gauge shows the pressure your installer set (typically about 1-2 bar); if it is low, report it rather than refilling unless you have been shown how. Check any filling loop is closed.
  • Check radiator valves / underfloor zones are open and thermostats are calling for heat.
  • In freezing weather keep the heat pump powered on (its frost protection relies on power) and check the outdoor unit is clear of snow/ice.

What the engineer will check

  • Follow the manufacturer's troubleshooting flowchart for this code.
  • Check water pressure, strainer/filter and air in the system.
  • Check circulation pump operation and flow sensor/switch.
  • Check heater safety thermostats and wiring.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026