E35 on a Haier Super Aqua R290 Hydro Split / Hydro All-in-One: Four Way Valve Reversing Abnormality

Short answer

On a Haier heat pump, E35 means: Four Way Valve Reversing Abnormality. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Four Way Valve Reversing Abnormality.

Part involved: compressor, pressure switch/sensor, expansion valve, refrigerant charge.

When it shows: 1. After the compressor is started, the continuous operation for 10 minutes does not meet the commutation pressure difference 6.0bar. 2. When the cooling 4WV OFF is running, the Two-Twi ≥ 1°C and the Tho-Two>5°C will report the fault for 5 consecutive minutes. When the heating 4WV ON is running, the Two-Twi ≤ -1°C and the Thi-Twi<0°C report the fault for 5 consecutive minutes. The fault is cleared after 3 minutes. If it occurs 3 times in an hour, confirm the failure.

Is it safe?

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes (until locked).

Manual reset: Locks out after repeated occurrences (see manual remark); engineer reset after the cause is fixed.

What you can check

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the outdoor unit is not blocked by leaves, debris, snow or ice and that nothing is stored against the grilles.

What the engineer will check

  • Follow the manufacturer's troubleshooting flowchart for this code.
  • Check refrigerant pressures and charge (F-gas / flammable refrigerant competent person only).
  • Check expansion valve, pressure switches/sensors and discharge temperature.
  • Check outdoor coil airflow and blockages.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.