E22 on a Haier Super Aqua R290 Hydro Split / Hydro All-in-One: Outdoor Compressor Suction Temperature Sensor Abnormality
Short answer
On a Haier heat pump, E22 means: Outdoor Compressor Suction Temperature Sensor Abnormality. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Outdoor Compressor Suction Temperature Sensor Abnormality.
Part involved: temperature/pressure sensor.
When it shows: If AD value is below 11 (open circuit) or over 1012 (short circuit) for 60 seconds, alarm.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Fault — clears by itself when the condition goes |
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
Resetting itself: yes.
What you can check
- Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
- Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
- Check the controller display is lit; a single power cycle at the isolator may be tried only if your installer or manual allows it.
What the engineer will check
- Follow the manufacturer's troubleshooting flowchart for this code.
- Check sensor connector and wiring.
- Measure sensor resistance against the manual's sensor table.
- Replace sensor or PCB as indicated by the troubleshooting flowchart.
Who to ask for: Heat pump engineer.
Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.
What you might notice
Sources
- R290 Super Aqua Hydro Split & Hydro All in One Service Manual - Service Diagnosis (SYJS-03-2024 REV.A) ↗ · SYJS-03-2024 REV.A · page p.45 (printed; PDF p.3) · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026