20 on a Haier heat pump: Defrosting temp.sensor (Te) failure

Short answer

On a Haier heat pump, 20 means: Defrosting temp.sensor (Te) failure. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Super Aqua Monobloc (R32, AU..FYCRA(HW))

The manual says: Defrosting temp.sensor (Te) failure.

Part involved: temperature/pressure sensor.

On the Super Aqua Split (R32, AW..SSCHA/SNCHA + HU..WAMNA)

The manual says: outdoor failure (indoor code) / Defrosting temp. sensor (Te) failure (outdoor code).

Is it safe?

On the Super Aqua Monobloc (R32, AU..FYCRA(HW))

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: unknown.

On the Super Aqua Split (R32, AW..SSCHA/SNCHA + HU..WAMNA)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

What you can check

On the Super Aqua Monobloc (R32, AU..FYCRA(HW))

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.
  • Check the controller display is lit; a single power cycle at the isolator may be tried only if your installer or manual allows it.

On the Super Aqua Split (R32, AW..SSCHA/SNCHA + HU..WAMNA)

  • Note the code shown on the controller and the unit model numbers (on the rating plate label) before contacting your installer.
  • Check the heat pump's breaker/isolator at the consumer unit is on; do not open any casing.

What the engineer will check

On the Super Aqua Monobloc (R32, AU..FYCRA(HW))

  • Follow the manufacturer's troubleshooting flowchart for this code.
  • Check sensor connector and wiring.
  • Measure sensor resistance against the manual's sensor table.
  • Replace sensor or PCB as indicated by the troubleshooting flowchart.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

On the Super Aqua Split (R32, AW..SSCHA/SNCHA + HU..WAMNA)

  • Follow the manufacturer's troubleshooting flowchart for this code.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas / flammable-refrigerant (R290/R32) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026