Danfoss heat pump error codes

Danfoss (heat pumps) · No longer sold new in the UK. 73 codes across 4 product families, each taken from the manufacturer’s manuals. Danfoss technical support ↗

Find a Danfoss engineer →73 codes · reviewed 23 September 2026

Filter by product family

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

73 codes

CodeMeaningStops?Homeowner check?
00
Communication failure
YesYes
01
Return water sensor (T9) failure
PartlyYes
02
Supply water sensor (T8) failure
PartlyYes
03
Water flow switch protection
YesYes
04
Phase sequence error (only applies to 3-phase models)
YesYes
05
Excessive temperature difference between supply and return water (>13°C)
YesYes
06
Internal electrical heater overheat protection (>85°C)
PartlyYes
07
Condenser overheat protection
YesYes
08
Hot water tank sensor (T3) failure
PartlyYes
09
Buffer tank sensor (T2) failure
PartlyYes
10
High pressure protection
YesYes
11
Low pressure protection
YesYes
12
Supply water temperature too high
YesYes
13
Supply water temperature too low (cooling mode only)
YesYes
14
Return gas temperature sensor (T5) failure
YesYes
15
Exhaust gas temperature sensor (T4) failure
YesYes
16
Exhaust gas temperature overheat protection
YesYes
18
Frost protection, step 2 (non-fault)
NoYes
19
Frost protection, step 1 (non-fault)
NoYes
20
Air temperature sensor (T1) failure
PartlyYes
21
Heating coil sensor (T7) failure
PartlyYes
22
Cooling coil sensor (T6) failure
PartlyYes
23
Exceeded operation range warning (non-fault)
NoYes
alarm-brine-pump
The brine pump's integrated alarm has deployed (Opti models only) - pump air-locked or jammed; integrated shake function tries up to 5 times before alarming.
YesYes
alarm-circulation-pump
The circulation pump's integrated alarm has deployed (Opti models only) - pump air-locked or jammed; shake function tries up to 5 times.
YesYes
aux-heater
Overheating protection deployed. No auxiliary heater.
PartlyYes
brine-out
Brine out is less than the set minimum temperature. Compressor stopped. No hot water production.
YesYes
brineflow-low
Flow sensor not active during last start. Compressor stopped. No hot water production.
YesYes
buffer-tank-sensor
Sensor fault alternatively cable fault.
PartlyYes
com-error-expansion-card
Communication broken between display card and expansion card (indoor).
PartlyYes
com-error-exv-card
Communication broken between display card and expansion valve control card (outdoor).
YesYes
com-error-hp-card
Communication broken between display card and heat pump card (outdoor).
YesYes
com-error-hub-card
Communication broken between display card and hub card (indoor).
YesYes
defrost-sensor
Sensor fault alternatively cable fault. Defrost sensor.
PartlyYes
discharge-pipe-sensor
Sensor fault alternatively cable fault.
PartlyYes
distr-cir-1-sensor
Sensor fault alternatively cable fault.
PartlyYes
distr-cir-2-sensor
Sensor fault alternatively cable fault.
PartlyYes
el-heater-error
The electrical heater overheating protection has deployed.
PartlyYes
err-phase-seq
Alarm that indicates that there is an incorrect phase sequence to the compressor. Only display and only the first 10 minutes.
Not statedYes
failsafe-mode
Sensor fault alternatively cable fault on one of the refrigerant sensors. The heat pump goes to failsafe mode and defrosts on time.
PartlyYes
heat-pressure-error
The expected pressure and temperature change in the refrigerant circuit has not happened in the correct way at compressor start.
YesYes
heating-circ-pump
Circulation pump is jammed.
YesYes
heating-system-pump
Circulation pump is jammed.
PartlyYes
hgw-sensor
Sensor fault alternatively cable fault.
PartlyYes
high-pressure
Class A alarm. The heating circuit is the heat pump's high pressure circuit - check the circuit's level (pressure) and acknowledge.
YesYes
high-pressure-error
High pressure switch has deployed.
YesYes
high-return
Alarm that indicates that high return temperature prevents the compressor's operation.
PartlyYes
high-return-line-temp
Return line temperature too high
PartlyYes
hot-water-sensor
Sensor fault alternatively cable fault (the lower sensor, Start sensor).
PartlyYes
hot-water-top
Sensor fault alternatively cable fault.
PartlyYes
low-evap-temp-1
Evaporation temperature too low.
YesYes
low-evap-temp-2
Too great a deviation in evaporation temperature average value.
YesYes
low-heat-cir-flow
The flow sensor has registered too low a flow.
YesYes
low-pressure
Class A alarm. The coolant (brine) circuit is the heat pump's low pressure circuit - check the circuit's level; contact a service technician if the alarm reoccurs.
YesYes
low-pressure-error
Evaporation pressure has fallen too low.
YesYes
low-pressure-transducer
Fault in low pressure transmitter alternatively cable fault.
YesYes
low-return-temp-1
The return line temperature is too low to start a defrosting.
PartlyYes
low-return-temp-2
The return line has fallen too low during defrosting.
PartlyYes
max-temp-elec-hw
Too high temperature in heat pump junction box/electrical cabinet.
Not statedYes
motor-p-comp-error
The compressor motor protection has deployed.
YesYes
motor-p-error
Deployed overload relay (overcurrent relay) for compressor or outdoor-unit fan; on certain models alarms from the brine pump or soft starter can also occur. Compressor stopped.
YesYes
motor-p-fan-error
The fan motor protection has deployed.
YesYes
no-of-tries-x-5
Circulation pump is jammed. Start attempt made.
PartlyYes
outdoor-sensor
Sensor fault alternatively cable fault.
PartlyYes
pool-sensor
Sensor fault alternatively cable fault.
NoYes
refr-1-sensor
Sensor fault alternatively cable fault. Refrigerant sensor 1
PartlyYes
refr-2-sensor
Sensor fault alternatively cable fault. Refrigerant sensor 2
PartlyYes
return-line-sensor
Sensor fault alternatively cable fault. Return line sensor.
PartlyYes
room-sensor
Sensor fault alternatively cable fault.
NoYes
sensor-cooling
Sensor fault. Cooling function stops.
PartlyYes
suction-temp-sensor
Sensor fault alternatively cable fault.
PartlyYes
supply-line-sensor
Sensor fault alternatively cable fault. Supply line sensor.
Varies by modelYes
system-supply-line-sensor
Sensor fault alternatively cable fault. System supply line sensor.
PartlyYes