el-heater-error on a Danfoss DHP-AQ: The electrical heater overheating protection has deployed

Short answer

On a Danfoss heat pump, el-heater-error means: The electrical heater overheating protection has deployed. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: The electrical heater overheating protection has deployed.

Part involved: immersion heater overheat protection.

Likely causes:

  • Overheat protection tripped; phase drop (no 230 V between L2 and N unless MAX STEP=P); faulty overheat protection; flow sensor fault; no/insufficient circulation.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Manual reset: Set operating mode OFF then back to the desired mode.

What you can check

  • Note the exact alarm text. Check the heating-system pressure gauge is in the range given in the user guide (Thermia/Danfoss: 1-1.5 bar when cold) - do not top up yourself unless you have been shown how; check radiator/underfloor valves and room thermostats are open. The manual allows acknowledging by setting operating mode OFF then back once; if the alarm returns, call an engineer.

What the engineer will check

  • Reset overheat protection; check cables; measure 230 V across protector; check flow sensor; check pump, valves, strainer, air.

Who to ask for: heat pump engineer.

Certification: Qualified electrician / heat pump engineer (electrical fault-finding).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026