high-pressure-error on a Danfoss heat pump: High pressure switch has deployed

Short answer

On a Danfoss heat pump, high-pressure-error means: High pressure switch has deployed. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the DHP-AQ

The manual says: High pressure switch has deployed.

Part involved: high pressure switch.

Likely causes:

  • Air in heating system; blocked strainer; closed thermostats/valves; defective/jammed circulation pump; closed main tap; cable break to HP switch; wrong/faulty HP switch; timer shunt closing circuit; non-return valve wrong way or too stiff; large pressure drop; blocked condenser (water or refrigerant side); overfilled refrigerant circuit.

On the DHP-H

The manual says: Tripped high pressure switch. Compressor stopped.

Part involved: high pressure switch.

Likely causes:

  • Blocked strainer in heating system; air in heating system; closed/partly closed thermostats or valves; defective or jammed circulation pump; closed main tap in heating system; broken/loose cable to HP switch; faulty or wrong HP switch; timer-controlled shunt closing heating circuit; wrong-way or high-opening-pressure non-return valve; large pressure drop in heating system; overfilled refrigerant circuit; condenser blocked (water or refrigerant side).

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: Set operating mode OFF then back to the desired mode.

What you can check

On the DHP-AQ

  • Note the exact alarm text. Check the heating-system pressure gauge is in the range given in the user guide (Thermia/Danfoss: 1-1.5 bar when cold) - do not top up yourself unless you have been shown how; check radiator/underfloor valves and room thermostats are open. The manual allows acknowledging by setting operating mode OFF then back once; if the alarm returns, call an engineer.

On the DHP-H

  • Note the exact alarm text. The manual allows acknowledging by setting the operating mode to OFF and then back to the previous mode - do this once; if the alarm returns, leave it and call an engineer. Check the heating-system pressure gauge is in the range given in the user guide (Thermia/Danfoss: 1-1.5 bar when cold) - do not top up yourself unless you have been shown how; check radiator/underfloor valves and room thermostats are open.

What the engineer will check

On the DHP-AQ

  • Bleed heating system; clean strainer; check pump voltage and 0-10 V signal; check HP switch and cabling; check non-return valve; condenser dT test (<3 K or >13 K suggests blockage); check charge.

Who to ask for: heat pump engineer.

Certification: F-Gas category I certificate (refrigerant circuit work).

On the DHP-H

  • Clean heating strainer; bleed heating system; verify circulation pump voltage/rotation via manual test menu; check HP switch cabling and break pressure (R407C HP switch 3.10 MPa, R404A 3.10 MPa) with gauges; check non-return valve orientation; check superheat/charge; test condenser dT (<3 K or >13 K suggests blockage).

Who to ask for: heat pump engineer.

Certification: F-Gas category I certificate (refrigerant circuit work).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026