Heat pumps · Error codes · Danfoss
motor-p-comp-errorDanfoss · DHP-AQ

motor-p-comp-error on a Danfoss DHP-AQ: The compressor motor protection has deployed

Short answer

On a Danfoss heat pump, motor-p-comp-error means: The compressor motor protection has deployed. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: The compressor motor protection has deployed.

Part involved: compressor motor protection, soft starter.

Likely causes:

  • Phase drop or blown fuse; cable break; defective soft starter (3-phase or single-phase); defective/incorrectly set motor protection; defective compressor; single-phase soft-starter alarm.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: Set operating mode OFF then back to the desired mode.

What you can check

  • Note the exact alarm text. Check the heat pump's breaker/isolator at the consumer unit is on and has not tripped. The manual allows acknowledging by setting operating mode OFF then back once; if the alarm returns, call an engineer.

What the engineer will check

  • Check all phases and fuses; check soft starter releases phases when heat pump card signals (A1-A2 or ON-N); clamp compressor current vs setting; check windings; read soft-start LEDs.

Who to ask for: heat pump engineer.

Certification: Qualified electrician / heat pump engineer (electrical fault-finding).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026