no-of-tries-x-5Danfoss · DHP-AQ

no-of-tries-x-5 on a Danfoss DHP-AQ: Circulation pump is jammed. Start attempt made

Short answer

On a Danfoss heat pump, no-of-tries-x-5 means: Circulation pump is jammed. Start attempt made. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Circulation pump is jammed. Start attempt made.

Part involved: circulation pump.

Likely causes:

  • Circulation pump jammed or air-locked; integrated shake function attempts up to 5 restarts (X = 1...5).

Is it safe?

Does the heat pump stop?Partly
SeverityInformation only
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

What you can check

  • Note the exact alarm text. Check the heating-system pressure gauge is in the range given in the user guide (Thermia/Danfoss: 1-1.5 bar when cold) - do not top up yourself unless you have been shown how; check radiator/underfloor valves and room thermostats are open. The manual allows acknowledging by setting operating mode OFF then back once; if the alarm returns, call an engineer.

What the engineer will check

  • Vent heating system and TWS coil; cut power, manually run pump; replace if recurring.

Who to ask for: heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.