alarm-brine-pump on a Danfoss DHP-H: The brine pump's integrated alarm has deployed (Opti models only) - pump air-locked or jammed; integrated shake function tries up to 5 times before alarming

Short answer

On a Danfoss heat pump, alarm-brine-pump means: The brine pump's integrated alarm has deployed (Opti models only) - pump air-locked or jammed; integrated shake function tries up to 5 times before alarming. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: The brine pump's integrated alarm has deployed (Opti models only) - pump air-locked or jammed; integrated shake function tries up to 5 times before alarming.

Part involved: speed-controlled brine pump.

Likely causes:

  • Air in brine pump; jammed brine pump.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: Set operating mode OFF then back to the desired mode.

What you can check

  • Note the exact alarm text. The manual allows acknowledging by setting the operating mode to OFF and then back to the previous mode - do this once; if the alarm returns, leave it and call an engineer. Look at the brine expansion tank: the fluid level should be visible (user guide check). Do not refill or open the ground-loop circuit yourself - call the installer.

What the engineer will check

  • Bleed brine circuit; cut power to clear alarm and manually run pump; repeat; replace pump if recurring; check 0-10 V control signal (troubleshooting guide p.13).

Who to ask for: heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.