Heat pumps · Error codes · Danfoss
alarm-circulation-pumpDanfoss · DHP-H

alarm-circulation-pump on a Danfoss DHP-H: The circulation pump's integrated alarm has deployed (Opti models only) - pump air-locked or jammed; shake function tries up to 5 times

Short answer

On a Danfoss heat pump, alarm-circulation-pump means: The circulation pump's integrated alarm has deployed (Opti models only) - pump air-locked or jammed; shake function tries up to 5 times. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: The circulation pump's integrated alarm has deployed (Opti models only) - pump air-locked or jammed; shake function tries up to 5 times.

Part involved: speed-controlled heating circulation pump.

Likely causes:

  • Air in circulation pump; jammed circulation pump.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: Set operating mode OFF then back to the desired mode.

What you can check

  • Note the exact alarm text. The manual allows acknowledging by setting the operating mode to OFF and then back to the previous mode - do this once; if the alarm returns, leave it and call an engineer. Check the heating-system pressure gauge is in the range given in the user guide (Thermia/Danfoss: 1-1.5 bar when cold) - do not top up yourself unless you have been shown how; check radiator/underfloor valves and room thermostats are open.

What the engineer will check

  • Bleed heating system; cut power and manually run pump; replace if recurring; check 0-10 V signal (troubleshooting guide p.12).

Who to ask for: heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.