Heat pumps · Error codes

LG heat pump error codes

LG · A major brand in the UK. 100 codes across 6 product families, each taken from the manufacturer’s manuals. LG technical support ↗

Find a LG engineer →100 codes · reviewed 23 September 2026

Filter by product family

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

100 codes

CodeMeaningStops?Homeowner check?
bc21
Inverter compressor IPM defect – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc22
Inverter compressor overcurrent – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc23
Inverter compressor DC link low voltage – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc25
High/low inverter input voltage – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc26
Inverter compressor activation failure – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc27
Inverter PSC/PFC fault error – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc28
Inverter DC link high voltage error – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc29
Inverter compressor overcurrent – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc32
Excessive rise of inverter compressor discharge temperature – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc34
Excessive rise of high pressure of inverter compressor – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc35
Excessive drop of low pressure of inverter compressor – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc36
Low pressure ratio error of inverter compressor – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc40
Inverter compressor CT sensor defect – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc41
Inverter compressor discharge pipe temperature sensor defect – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc42
Low pressure sensor defect of inverter compressor – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc43
High pressure sensor defect of inverter compressor – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc44
Inverter inside air temperature sensor defect – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc46
Inverter compressor suction pipe temperature sensor defect – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc53
Communication error (indoor unit → outdoor unit main PCB) – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc60
Inverter PCB EEPROM error – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc62
Excessive rise of inverter heatsink temperature – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc65
Inverter heatsink temperature sensor defect – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
bc73
Overcurrent (peak) detected at inverter input – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).
YesYes
CH01
Problem in remote (room) air temperature sensor – sensor on the indoor Main PCB/remote room sensor is open or short circuit.
PartlyYes
CH02
Problem in refrigerant inlet (liquid) side pipe temperature sensor of indoor unit – open or short.
PartlyYes
CH03
Bad communication between wired remote controller and indoor unit (Main PCB(Indoor) does not receive the remote controller signal).
YesYes
CH04
Condensate drain is blocked (THERMA V water heater).
PartlyYes
CH05
Communication error between indoor unit Main PCB and outdoor unit (Main PCB(Outdoor cycle)/inverter PCB) – indoor does not receive the outdoor signal.
PartlyYes
CH06
Problem in refrigerant outlet (gas) side pipe temperature sensor of indoor unit – open or short.
Varies by modelYes
CH08
Problem in domestic hot water (DHW) tank temperature sensor – open or short.
PartlyYes
CH09
Indoor PCB program (EEPROM) fault – optional EEPROM loosely inserted, removed, burnt, or data mismatched.
Varies by modelYes
CH10
BLDC water (circulation) pump lock – restriction or wrong connection of the BLDC water pump.
YesYes
CH11
Indoor unit & inverter PCB communication error (High Temperature split).
Varies by modelYes
CH12
Inverter PCB error (High Temperature split) – error occurrence in the indoor inverter PCB (see bc codes).
Varies by modelYes
CH13
Problem in solar-thermal (solar pipe) temperature sensor – open or short.
PartlyYes
CH14
Water flow problem – low flow detected during pump operation (flow sensor models) or flow switch open while the internal pump runs / closed while it is stopped (flow switch models).
YesYes
CH15
Water pipe overheated – leaving water temperature exceeded the protection limit.
YesYes
CH16
Problems in sensors – water-inlet, water-outlet and backup-heater outlet sensors (CH17/18/19) fail at the same time.
YesYes
CH17
Problem in water-inlet (return / PHEX inlet) temperature sensor – open or short.
PartlyYes
CH18
Problem in water-outlet (flow / PHEX outlet) temperature sensor – open or short.
PartlyYes
CH19
Problem in electric backup heater water-outlet (water-interim) temperature sensor – open or short.
PartlyYes
CH20
Electric (backup) heater overheated – thermal fuse / thermo switch cut out.
Varies by modelYes
CH21
DC peak (IPM / IGBTM fault) – compressor stopped to protect the power module after detecting its fault-out signal; inverter drive IPM or compressor defective.
PartlyYes
CH22
Max CT / CT2 current error – input over-current to the outdoor unit (inverter PCB power input exceeded).
PartlyYes
CH23
DC link voltage low or high – inverter DC-link not charging or outside limits.
PartlyYes
CH24
High pressure (switch) error – compressor stopped by the high-pressure (or low/high pressure) switch.
PartlyYes
CH25
Inverter input voltage too high or too low.
PartlyYes
CH26
DC compressor position / start-up failure (no position error, locking detection) – inverter compressor fails to start.
PartlyYes
CH27
PSC/PFC fault – AC input instant over-current / over-current in PFC module.
PartlyYes
CH28
DC link high voltage – inverter DC-link voltage too high after inverter relay on.
PartlyYes
CH29
Inverter compressor over-current (compressor phase current exceeds limit).
PartlyYes
CH32
High discharge-pipe temperature of the inverter compressor – compressor switched off.
PartlyYes
CH34
High pressure error – condensing pressure excessively high (compressor off).
PartlyYes
CH35
Low pressure error – evaporating pressure excessively low.
PartlyYes
CH36
Low pressure ratio error of inverter compressor – outdoor unit (R410A stage) error on High Temperature split; shown on outdoor 7-segment LED with unit number suffix (e.g. "36 1") and on the indoor display/remote controller.
PartlyYes
CH37
Pressure ratio too high – R410A Monobloc.
PartlyYes
CH40
Inverter compressor CT sensor error – compressor control impossible due to CT sensor fault in inverter driver.
PartlyYes
CH41
Inverter compressor discharge-pipe temperature sensor error (open/short).
PartlyYes
CH42
Low pressure sensor defect of inverter compressor – outdoor unit (R410A stage) error on High Temperature split; shown on outdoor 7-segment LED with unit number suffix (e.g. "42 1") and on the indoor display/remote controller.
PartlyYes
CH43
High pressure sensor error (open/short).
PartlyYes
CH44
Outdoor air (ambient) temperature sensor error (open/short).
PartlyYes
CH45
Condenser middle-pipe (outdoor heat-exchanger) temperature sensor error (open/short).
PartlyYes
CH46
Compressor suction-pipe temperature sensor error (open/short).
PartlyYes
CH47
Const-D-pipe sensor error (open/short) – R32 Monobloc Gen1.
PartlyYes
CH48
Condenser out-pipe temperature sensor error (open/short) – thermistor not inserted or inserted incorrectly.
PartlyYes
CH49
Defective IPM temperature sensor – outdoor unit (R410A stage) error on High Temperature split; shown on outdoor 7-segment LED with unit number suffix (e.g. "49 1") and on the indoor display/remote controller.
PartlyYes
CH52
Communication error between inverter PCB (outdoor) and Main PCB (outdoor cycle).
YesYes
CH53
Communication error: outdoor unit fails to receive signal from indoor unit (Main PCB(Indoor) → Main PCB(Outdoor)).
PartlyYes
CH54
Open-phase / reverse-phase (R-S-T) error – mains wiring fault on 3-phase models.
PartlyYes
CH55
Modbus communication error (Modbus ↔ indoor PCB) – R290 Monobloc.
Not statedYes
CH57
Communication error between Main PCB (outdoor cycle) and inverter PCB (outdoor) (Hydrosplit/R290 list: "Main PCB(Indoor) → Inv PCB(Outdoor)").
PartlyYes
CH60
Outdoor EEPROM error – EEPROM access error / checksum mismatch.
PartlyYes
CH61
High temperature in condenser pipe (condensing pressure too high).
PartlyYes
CH62
Heatsink temperature high – inverter PCB heatsink/power element overheated.
PartlyYes
CH63
Condenser-pipe temperature too low – R410A Monobloc.
PartlyYes
CH65
Heatsink temperature sensor error (open/short) – heatsink or PSCM/PFCM internal sensor cannot be read.
PartlyYes
CH67
Outdoor BLDC fan lock.
PartlyYes
CH73
Overcurrent (peak) detected at inverter input – AC input instant over-current.
PartlyYes
CH86
Outdoor unit Main PCB EEPROM error – outdoor unit (R410A stage) error on High Temperature split; shown on outdoor 7-segment LED with unit number suffix (e.g. "86 1") and on the indoor display/remote controller.
YesYes
CH88
PFC (inverter PCBA) EEPROM error – communication fail between PFC micom and its EEPROM.
PartlyYes
CH113
Outdoor unit liquid pipe temperature sensor error – outdoor unit (R410A stage) error on High Temperature split; shown on outdoor 7-segment LED with unit number suffix (e.g. "113 1") and on the indoor display/remote controller.
PartlyYes
CH114
Vapour-injection inlet pipe temperature sensor error (open/short).
PartlyYes
CH115
Vapour-injection outlet pipe temperature sensor error (open/short).
PartlyYes
CH117
Condenser in-pipe temperature sensor error (open/short) – thermistor not inserted or inserted incorrectly (R290).
PartlyYes
CH145
Communication error between Sub PCB (outdoor) and Main PCB (outdoor cycle) – R290.
PartlyYes
CH151
Failure of operation mode conversion at outdoor unit – outdoor unit (R410A stage) error on High Temperature split; shown on outdoor 7-segment LED with unit number suffix (e.g. "151 1") and on the indoor display/remote controller.
YesYes
CH231
Problem in water pressure sensor – sensor damaged or incorrectly connected.
PartlyYes
CH232
Problem in water flow sensor – flow sensor damaged or incorrectly connected.
YesYes
CH233
Problem in solar thermal sensor (open/short) – R290.
PartlyYes
CH234
Problem in buffer tank temperature sensor (open/short) – R290.
PartlyYes
CH235
Problem in (wall-mounted) ambient temperature sensor (open/short) – R290.
PartlyYes
CH237
Communication modem error – RS-485 modem on the indoor (IDU 485 modem) cannot communicate with Main PCB (outdoor cycle) (R290).
YesYes
CH238
Communication modem error – RS-485 modem on the outdoor (ODU 485 modem) cannot communicate with Main PCB (outdoor cycle) (R290).
YesYes
DF
No or not enough water in tank (THERMA V water heater).
YesYes
EC
ECO (energy cut-off / high-limit safety) is tripped (THERMA V water heater).
YesYes
H1
Water temperature is too high (THERMA V water heater).
YesYes
H2
Water temperature is too high (THERMA V water heater).
YesYes
IC
ICCP (impressed-current cathodic protection anode) is not functioning (THERMA V water heater).
YesYes
L1
Water temperature is too low (THERMA V water heater).
YesYes
L2
Water temperature is too low or upper tank temperature sensor is not working (THERMA V water heater).
YesYes