CH20 on a LG heat pump: Electric (backup) heater overheated – thermal fuse / thermo switch cut out

Short answer

On a LG heat pump, CH20 means: Electric (backup) heater overheated – thermal fuse / thermo switch cut out. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LG, all models

The manual says: Electric (backup) heater overheated – thermal fuse / thermo switch cut out.

Part involved: backup heater thermal fuse / thermo switch (CN_SOLAR/CN_THMO).

When it shows: Heater tank/outlet temperature >= 80 °C (thermal fuse).

Likely causes:

  • Thermal fuse cut off by abnormal overheating of internal electric heater (e.g. air in heater vessel, no flow); mechanical fault at thermal fuse; wiring wrong or damaged.

On the THERMA V Water Heater (heat pump DHW cylinder)

The manual says: Lower element is not working (THERMA V water heater).

Part involved: electric heating element.

When it shows: Lower element is not working.

Likely causes:

  • Lower element is not working.

Is it safe?

On the LG, all models

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Service-engineer repair and restart required (LG: resumed only after certificated professional's check).

On the THERMA V Water Heater (heat pump DHW cylinder)

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: unknown.

Manual reset: Per LG corrective action; service engineer for most codes.

What you can check

On the LG, all models

  • Read the code on the controller (LG shows 'CH' + number; older wired controllers alternate 'CH' and the number) and note it together with the model number. Report it to your installer or an LG-authorised service centre – LG owner's manuals say an error code generated by self-diagnosis is a reason to call the service. This is an 'Error'-class fault: LG says the system can only be resumed after a qualified professional has checked it, so do not keep trying to restart it. If you notice a burning smell, switch the heat pump off at its isolator/breaker and call the service.

On the THERMA V Water Heater (heat pump DHW cylinder)

  • Note the code shown on the water heater display. LG's corrective action: call LG technical support. While the fault is present the unit operates as: Use heat pump only – hot water will be heated more slowly/at higher cost.

What the engineer will check

On the LG, all models

  • Check harness on PCB, test thermo switch/thermal fuse continuity, find cause of overheat (flow, air); 1ph models: manual reset button on thermo switch; 3ph models: auto reset once below 70 °C then re-power. Replace thermo switch or heater.

Who to ask for: Heat pump engineer / electrician (inverter and PCB diagnostics).

Certification: Competent person for electrical work (BS 7671); isolate and wait 3 min for DC-link discharge.

On the THERMA V Water Heater (heat pump DHW cylinder)

  • Isolate; test element resistance and insulation, relay output and wiring; replace element.

Who to ask for: Heat pump engineer / electrician (inverter and PCB diagnostics).

Certification: Competent person for electrical work (BS 7671); isolate and wait 3 min for DC-link discharge.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026