CH06LG

CH06 on a LG heat pump: Problem in refrigerant outlet (gas) side pipe temperature sensor of indoor unit – open or short

Short answer

On a LG heat pump, CH06 means: Problem in refrigerant outlet (gas) side pipe temperature sensor of indoor unit – open or short. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LG, all models

The manual says: Problem in refrigerant outlet (gas) side pipe temperature sensor of indoor unit – open or short.

Part involved: refrigerant outlet (gas) pipe thermistor.

When it shows: Sensor open/short (5 kΩ at 25 °C unplugged, 2.5 V DC plugged).

Likely causes:

  • Incorrect connection between sensor and PCB; PCB fault; sensor fault.

On the THERMA V Water Heater (heat pump DHW cylinder)

The manual says: Lower tank temperature sensor is not working (THERMA V water heater).

Part involved: thermistor.

When it shows: Lower tank temperature sensor is not working.

Likely causes:

  • Lower tank temperature sensor is not working.

Is it safe?

On the LG, all models

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes – trouble clears when the condition is repaired; emergency operation must be restarted by the user after a power reset.

Manual reset: Not normally required; user restarts after power reset if emergency operation was running.

On the THERMA V Water Heater (heat pump DHW cylinder)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Per LG corrective action; service engineer for most codes.

What you can check

On the LG, all models

  • Read the code on the controller (LG shows 'CH' + number; older wired controllers alternate 'CH' and the number) and note it together with the model number. Report it to your installer or an LG-authorised service centre – LG owner's manuals say an error code generated by self-diagnosis is a reason to call the service. For this 'trouble' class LG allows temporary emergency operation: if the controller shows a pop-up offering it you may accept (OK) as a stop-gap; running costs will be higher, so do not use it long term. Emergency operation does not restart by itself after a power cut – you must switch it back on at the controller.

On the THERMA V Water Heater (heat pump DHW cylinder)

  • Note the code shown on the water heater display. LG's corrective action: call LG technical support. While the fault is present the unit operates as: OFF – no hot water from this unit.

What the engineer will check

On the LG, all models

  • Check the thermistor is fully inserted in its pocket/holder and the connector is seated on the correct PCB header; measure resistance unplugged (LG: pipe/water sensors 5 kΩ at 25 °C, room air sensor 10 kΩ at 25 °C, D-pipe sensor ~200 kΩ at 25 °C) and voltage plugged (~2.2–2.5 V DC at 25 °C) against LG resistance-temperature tables; replace sensor, then PCB if readings are correct.

Who to ask for: Heat pump engineer (controls, sensors, PCB).

Certification: None statutory beyond electrical competence (BS 7671).

On the THERMA V Water Heater (heat pump DHW cylinder)

  • Check the thermistor is fully inserted in its pocket/holder and the connector is seated on the correct PCB header; measure resistance unplugged (LG: pipe/water sensors 5 kΩ at 25 °C, room air sensor 10 kΩ at 25 °C, D-pipe sensor ~200 kΩ at 25 °C) and voltage plugged (~2.2–2.5 V DC at 25 °C) against LG resistance-temperature tables; replace sensor, then PCB if readings are correct.

Who to ask for: Heat pump engineer / electrician (inverter and PCB diagnostics).

Certification: Competent person for electrical work (BS 7671); isolate and wait 3 min for DC-link discharge.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026