Heat pumps · Error codes · LG
bc62LG · THERMA V High Temperature Split

bc62 on a LG THERMA V High Temperature Split: Excessive rise of inverter heatsink temperature – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split)

Short answer

On a LG heat pump, bc62 means: Excessive rise of inverter heatsink temperature – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Excessive rise of inverter heatsink temperature – indoor-unit (R134a stage) inverter PCB error, displayed with prefix "bc" (High Temperature split).

Part involved: indoor R134a inverter compressor / inverter PCB.

When it shows: Inverter PCB heat generation, causing the rise of heatsink temperature.

Likely causes:

  • Inverter PCB heat generation, causing the rise of heatsink temperature.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Service-engineer repair and restart required (LG: resumed only after certificated professional's check).

What you can check

  • Read the code on the controller (LG shows 'CH' + number; older wired controllers alternate 'CH' and the number) and note it together with the model number. Report it to your installer or an LG-authorised service centre – LG owner's manuals say an error code generated by self-diagnosis is a reason to call the service. This is an 'Error'-class fault: LG says the system can only be resumed after a qualified professional has checked it, so do not keep trying to restart it.

What the engineer will check

  • Isolate and wait at least 3 minutes for DC-link capacitors to discharge. Check supply voltage (1ph 230 V ±15 %, 3ph 400 V ±15 %), outdoor fan free to rotate and heat exchanger unobstructed, service valves open, EEV operation, refrigerant charge/pressures (LGMV), compressor U-V-W wiring, winding resistance and insulation resistance, IPM/IGBTM diode test, then replace inverter PCB or compressor as indicated by LGMV fault-finding.

Who to ask for: Heat pump engineer / electrician (inverter and PCB diagnostics).

Certification: Competent person for electrical work (BS 7671); isolate and wait 3 min for DC-link discharge.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026