CH37LG · THERMA V Monobloc (R410A)

CH37 on a LG THERMA V Monobloc: Pressure ratio too high – R410A Monobloc

Short answer

On a LG heat pump, CH37 means: Pressure ratio too high – R410A Monobloc. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Pressure ratio too high – R410A Monobloc.

Part involved: refrigerant circuit.

When it shows: Pressure ratio above limit.

Likely causes:

  • Refrigerant-cycle abnormality (high discharge/low suction ratio).

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes – trouble clears when the condition is repaired; emergency operation must be restarted by the user after a power reset.

Manual reset: Not normally required; user restarts after power reset if emergency operation was running.

What you can check

  • Read the code on the controller (LG shows 'CH' + number; older wired controllers alternate 'CH' and the number) and note it together with the model number. Report it to your installer or an LG-authorised service centre – LG owner's manuals say an error code generated by self-diagnosis is a reason to call the service. For this 'trouble' class LG allows temporary emergency operation: if the controller shows a pop-up offering it you may accept (OK) as a stop-gap; running costs will be higher, so do not use it long term. Emergency operation does not restart by itself after a power cut – you must switch it back on at the controller.

What the engineer will check

  • Check refrigerant charge, EEV, fan, water flow; LGMV pressures.

Who to ask for: Heat pump engineer with LG Therma V training; F-gas certified refrigeration engineer for refrigerant-circuit work.

Certification: F-gas certification (UK F-gas Regulation, Category I) for any refrigerant handling on R32/R410A units; for R290 units additionally competence in flammable (hydrocarbon) refrigerants (e.g. BESA/ACRIB HC safe handling).

What you might notice

What owners and engineers report

2 owner and engineer reports mention this.

  • Keeps stopping / cutting out on the THERMA V Monobloc (R410A): 1 report
  • No heating on the THERMA V Monobloc (R410A): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026