Heat pumps · Error codes · LG
CH40LG · LG, all models

CH40 on a LG heat pump: Inverter compressor CT sensor error – compressor control impossible due to CT sensor fault in inverter driver

Short answer

On a LG heat pump, CH40 means: Inverter compressor CT sensor error – compressor control impossible due to CT sensor fault in inverter driver. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Inverter compressor CT sensor error – compressor control impossible due to CT sensor fault in inverter driver.

Part involved: inverter PCB CT sensor.

When it shows: CT sensor reading invalid.

Likely causes:

  • CT sensor defect on inverter PCB.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes – trouble clears when the condition is repaired; emergency operation must be restarted by the user after a power reset.

Manual reset: Not normally required; user restarts after power reset if emergency operation was running.

What you can check

  • Read the code on the controller (LG shows 'CH' + number; older wired controllers alternate 'CH' and the number) and note it together with the model number. Report it to your installer or an LG-authorised service centre – LG owner's manuals say an error code generated by self-diagnosis is a reason to call the service. For this 'trouble' class LG allows temporary emergency operation: if the controller shows a pop-up offering it you may accept (OK) as a stop-gap; running costs will be higher, so do not use it long term. Emergency operation does not restart by itself after a power cut – you must switch it back on at the controller. Check (without opening any panels) that the outdoor unit is not blocked by leaves, debris, snow or ice and that nothing is stacked against the coil or fan grille.

What the engineer will check

  • Check CT sensing circuit (5 V ±10 % at check point, Hydrosplit p.102); replace inverter PCB.

Who to ask for: Heat pump engineer / electrician (inverter and PCB diagnostics).

Certification: Competent person for electrical work (BS 7671); isolate and wait 3 min for DC-link discharge.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.