SolarpunkHomes
Sign inCall us · +44 7510 081687
Solar
Solar · Error codes · Sunsynk
F42Sunsynk · ECCO single-phase hybrid SG05LP1

F42 on a Sunsynk ECCO single-phase hybrid SG05LP1: Grid voltage fault (AC line low voltage)

Short answer

On a Sunsynk inverter, F42 means: Grid voltage fault (AC line low voltage). The inverter stops until the fault clears or is reset.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Grid voltage fault (AC line low voltage).

Part involved: grid voltage.

When it shows: Grid voltage below limit.

Likely causes:

  • Grid under-voltage; wiring connections; settings (also listed as Parallel_Version_Fault in parallel systems).

Is it safe?

Does the inverter stop?Yes
SeverityFault — clears by itself when the condition goes

The inverter stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Check voltage vs spec and grid set-up page; seek help.

What you can check

  • Read the full code and message on the inverter screen or in the Sunsynk Connect app and note the date/time for your installer.
  • Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).

What the engineer will check

  • Check grid voltage and AC cables; check grid set-up (UK G98/G99); in parallel systems align firmware versions.

Who to ask for: Installer, with DNO (network operator) if grid supply is at fault.

Certification: None for homeowner checks; any grid-protection setting change needs installer and DNO consent (G98/G99).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026