F13 on a Sunsynk ECCO single-phase hybrid SG05LP1: Working mode change - grid type/frequency changed, battery mode set to 'No battery', or (old firmware) system work mode changed
Short answer
On a Sunsynk inverter, F13 means: Working mode change - grid type/frequency changed, battery mode set to 'No battery', or (old firmware) system work mode changed. The inverter keeps running with some functions stopped.
Reviewed 24 September 2026 · 1 source
What it means
The manual says: Working mode change - grid type/frequency changed, battery mode set to 'No battery', or (old firmware) system work mode changed.
Part involved: operating mode.
When it shows: Mode/setting change or grid event.
Likely causes:
- Grid loss or reconnection; grid type or frequency changed; battery mode changed to 'No battery'; major settings change; old firmware reports it on any work-mode change.
Is it safe?
| Does the inverter stop? | Partly |
|---|---|
| Severity | Information only |
| Engineer needed? | No |
The inverter keeps running with some functions stopped.
Resetting itself: yes.
Manual reset: Generally disappears automatically; if not, DC and AC switches off, wait one minute, on.
What you can check
- Read the full code and message on the inverter screen or in the Sunsynk Connect app and note the date/time for your installer.
- Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).
- F13 usually clears by itself after a settings change or grid blip - check if anyone changed settings in the app.
- Sunsynk's documented restart: turn off the inverter's DC and AC switches, wait one minute, turn back on - only do this if your installer has shown you the safe shutdown/restart sequence; otherwise ask them.
What the engineer will check
- Review settings history; update firmware; check grid sensing.
Who to ask for: Qualified electrician / MCS PV installer.
Certification: Firmware/config change via installer portal; no special certification but installer access normally required.
What you might notice
Sources
- Fault Codes Causes & Solutions Version 1.0 ↗ · Version 1.0 · page 5 · Reviewed 24 September 2026
A code explains what the controller detected, not a confirmed root cause.