F13 on a Sunsynk ECCO single-phase hybrid SG05LP1: Working mode change - grid type/frequency changed, battery mode set to 'No battery', or (old firmware) system work mode changed

Short answer

On a Sunsynk inverter, F13 means: Working mode change - grid type/frequency changed, battery mode set to 'No battery', or (old firmware) system work mode changed. The inverter keeps running with some functions stopped.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Working mode change - grid type/frequency changed, battery mode set to 'No battery', or (old firmware) system work mode changed.

Part involved: operating mode.

When it shows: Mode/setting change or grid event.

Likely causes:

  • Grid loss or reconnection; grid type or frequency changed; battery mode changed to 'No battery'; major settings change; old firmware reports it on any work-mode change.

Is it safe?

Does the inverter stop?Partly
SeverityInformation only
Engineer needed?No

The inverter keeps running with some functions stopped.

Resetting itself: yes.

Manual reset: Generally disappears automatically; if not, DC and AC switches off, wait one minute, on.

What you can check

  • Read the full code and message on the inverter screen or in the Sunsynk Connect app and note the date/time for your installer.
  • Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).
  • F13 usually clears by itself after a settings change or grid blip - check if anyone changed settings in the app.
  • Sunsynk's documented restart: turn off the inverter's DC and AC switches, wait one minute, turn back on - only do this if your installer has shown you the safe shutdown/restart sequence; otherwise ask them.

What the engineer will check

  • Review settings history; update firmware; check grid sensing.

Who to ask for: Qualified electrician / MCS PV installer.

Certification: Firmware/config change via installer portal; no special certification but installer access normally required.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026