Solar · Error codes · Sunsynk
F24Sunsynk · ECCO single-phase hybrid SG05LP1

F24 on a Sunsynk ECCO single-phase hybrid SG05LP1: PV isolation resistance is too low

Short answer

On a Sunsynk inverter, F24 means: PV isolation resistance is too low. The inverter stops until the fault clears or is reset.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: PV isolation resistance is too low.

Part involved: PV array insulation.

When it shows: Insulation resistance below threshold.

Likely causes:

  • Earth fault on PV; + or - PV conductor touching ground.

Is it safe?

Switch the inverter off at its isolator and call an engineer.

Does the inverter stop?Yes
SeverityFault — clears by itself when the condition goes

The inverter stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: Seek help if it does not return to normal.

What you can check

  • Read the full code and message on the inverter screen or in the Sunsynk Connect app and note the date/time for your installer.
  • Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).
  • Do not touch panels, DC cables or DC switch; call your installer if it recurs.

What the engineer will check

  • Check PV-to-inverter connections; check inverter PE bonding; insulation-test each string.

Who to ask for: MCS-certified solar PV installer (DC/string work) or the original installer.

Certification: Work on DC strings and inverter enclosures: competent PV installer (MCS-certified installer for warranty/SEG continuity); electrical work notifiable under Part P (England & Wales) or equivalent.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026