Shenzhen SOFARSOLAR Co., Ltd. · An established brand in the UK. 38 codes across 2 product families, each taken from the manufacturer’s manuals. Shenzhen SOFARSOLAR Co., Ltd. technical support ↗
Filter by product family
Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.
38 codes
| Code | Meaning | Stops? | Homeowner check? |
|---|---|---|---|
| ID001 | The grid voltage is too high | Yes | Yes |
| ID01 | The grid voltage is too high | Yes | Yes |
| ID002 | The grid voltage is too low | Yes | Yes |
| ID02 | The grid voltage is too low | Yes | Yes |
| ID003 | The grid frequency is too high | Yes | Yes |
| ID03 | The grid frequency is too high | Yes | Yes |
| ID004 | The grid frequency is too low | Yes | Yes |
| ID04 | The grid frequency is too low | Yes | Yes |
| ID005 | Charge leakage fault (internal) | Yes | Yes |
| ID08 | The PV voltage is too high | Yes | Yes |
| ID09 | LLCBus voltage too high (hardware protection); ID09-ID12 internal faults | Yes | Yes |
| ID13 | GFCI sampling inconsistent / leakage; if frequent insulation resistance PV-earth may be too low | Yes | Yes |
| ID16 | Input current not balanced | Partly | Yes |
| ID17 | Grid current sampling error (ID17-ID26 internal faults) | Yes | Yes |
| ID34 | The load is overloaded | Partly | Yes |
| ID35 | The CT is faulty | Partly | Yes |
| ID042 | Low insulation impedance | Yes | Yes |
| ID043 | Ground fault | Yes | Yes |
| ID045 | CT error | Partly | Yes |
| ID046 | PV reverse connection | Yes | Yes |
| ID55 | Relay fault (ID53-ID55 internal faults) | Yes | Yes |
| ID56 | The insulation resistance is too low | Yes | Yes |
| ID57 | The battery temp is too high | Partly | Yes |
| ID58 | The temperature of heat sink is too high | Partly | Yes |
| ID59 | The environment temperature is too high | Partly | Yes |
| ID60 | Grounding not correct | Yes | Yes |
| ID069 | PV over-voltage | Yes | Yes |
| ID81 | Internal temperature too high (derating) | Partly | Yes |
| ID82 | AC frequency is too high | Partly | Yes |
| ID83 | Remote power derate | Partly | Yes |
| ID84 | Switch off HYD inverter remotely | Yes | Yes |
| ID094 | EPS short circuit protection | Partly | Yes |
| ID98 | The SD card is faulty | No | Yes |
| ID105 | Meter communication error | Partly | Yes |
| ID110 | Overload protection 1 | Partly | Yes |
| ID113 | Internal temperature is too high | Partly | Yes |
| ID116 | AC voltage is too high (derating) | Partly | Yes |
| ID146 | Wifi fault | No | Yes |