H01-5239 on a Worcester Bosch heat pump: DHW temp sensor TW1 fault
Short answer
On a Worcester Bosch heat pump, H01-5239 means: DHW temp sensor TW1 fault. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: DHW temp sensor TW1 fault.
Part involved: DHW sensor TW1.
When it shows: DHW temp sensor TW1 fault.
Likely causes:
- Sensor TW1/signal cable shorted or broken; defective installer board.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Fault — clears by itself when the condition goes |
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
Resetting itself: Clears when cause is removed.
Manual reset: User guides (7001i/7400i AWE, 3400i AWS, section 3.5): user may confirm the fault by pressing the selector; if it persists call the contractor with fault code, sub-code and user-interface ID no.
What you can check
- Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
- Confirm/acknowledge the fault once at the controller (press selector) as the user guide allows; if it returns, call the installer.
What the engineer will check
- Measure TW1 disconnected and compare to table; repair cable/replace sensor; replace installer board.
Who to ask for: heat pump installer / electrician.
Certification: Electrical work to BS 7671 by competent person.
What you might notice
Sources
- Installation instructions User interface HPC 410 ↗ · 6721832682 (2021/02) · page 19 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026