A01-5378 on a Worcester Bosch heat pump: Outdoor unit defrost failure

Short answer

On a Worcester Bosch heat pump, A01-5378 means: Outdoor unit defrost failure. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Outdoor unit defrost failure.

Part involved: outdoor unit defrost, sensor TL2.

When it shows: Outdoor unit defrost failure.

Likely causes:

  • Heating system temperature too low (open more thermostats); defective sensor TL2.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Clears when cause is removed.

Manual reset: User guides (7001i/7400i AWE, 3400i AWS, section 3.5): user may confirm the fault by pressing the selector; if it persists call the contractor with fault code, sub-code and user-interface ID no.

What you can check

  • Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
  • Make sure radiator/UFH thermostats are not all closed.
  • Check the outdoor unit is not blocked by leaves, snow, ice or other debris (do not open the casing).
  • Confirm/acknowledge the fault once at the controller (press selector) as the user guide allows; if it returns, call the installer.

What the engineer will check

  • Check TL2 against sensor table and replace if deviating.

Who to ask for: F-gas refrigeration engineer / heat pump installer.

Certification: F-gas certification (Category I) required for refrigerant circuit work; qualified electrician for electrical work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026