A01-5522 on a Worcester Bosch heat pump: Wrong combination of indoor and outdoor units

Short answer

On a Worcester Bosch heat pump, A01-5522 means: Wrong combination of indoor and outdoor units. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Wrong combination of indoor and outdoor units.

Part involved: I/O module / installer module coding.

When it shows: Wrong combination of indoor and outdoor units.

Likely causes:

  • Non-matching heat pump and indoor unit; replaced I/O module in heat pump or installer module in indoor unit with rotary encoder not set correctly.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: User guides (7001i/7400i AWE, 3400i AWS, section 3.5): user may confirm the fault by pressing the selector; if it persists call the contractor with fault code, sub-code and user-interface ID no.

What you can check

  • Read and note the full code (and sub-code) shown on the controller and pass it to your installer.
  • Confirm/acknowledge the fault once at the controller (press selector) as the user guide allows; if it returns, call the installer.

What the engineer will check

  • Check combination tables; set rotary encoder to match old module/wiring diagram.

Who to ask for: heat pump installer / controls engineer.

Certification: None specific; electrical isolation required before wiring checks.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.