Thermia heat pump error codes

Thermia · No longer sold new in the UK. 46 codes across 3 product families, each taken from the manufacturer’s manuals. Thermia technical support ↗

Find a Thermia engineer →46 codes · reviewed 23 September 2026

Filter by product family

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

46 codes

CodeMeaningStops?Homeowner check?
aux-heater
Overheating protection deployed. No auxiliary heater.
PartlyYes
brine-out
Brine out is less than the set minimum temperature. Compressor stopped. No hot water production.
YesYes
brineflow-low
Flow sensor not active during last start. Compressor stopped. No hot water production.
YesYes
buffer-tank-sensor
Sensor fault alternatively cable fault.
PartlyYes
com-error-expansion-card
Communication broken between display card and expansion card (indoor).
PartlyYes
com-error-exv-card
Communication broken between display card and expansion valve control card (outdoor).
YesYes
com-error-hp-card
Communication broken between display card and heat pump card (outdoor).
YesYes
com-error-hub-card
Communication broken between display card and hub card (indoor).
YesYes
defrost-sensor
Sensor fault alternatively cable fault. Defrost sensor.
PartlyYes
discharge-pipe-sensor
Sensor fault alternatively cable fault.
PartlyYes
distr-cir-1-sensor
Sensor fault alternatively cable fault.
PartlyYes
distr-cir-2-sensor
Sensor fault alternatively cable fault.
PartlyYes
el-heater-error
The electrical heater overheating protection has deployed.
PartlyYes
err-phase-seq
Alarm that indicates that there is an incorrect phase sequence to the compressor. Only display and only the first 10 minutes.
Not statedYes
failsafe-mode
Sensor fault alternatively cable fault on one of the refrigerant sensors. The heat pump goes to failsafe mode and defrosts on time.
PartlyYes
heat-pressure-error
The expected pressure and temperature change in the refrigerant circuit has not happened in the correct way at compressor start.
YesYes
heating-circ-pump
Circulation pump is jammed.
YesYes
heating-system-pump
Circulation pump is jammed.
PartlyYes
hgw-sensor
Sensor fault alternatively cable fault.
PartlyYes
high-pressure-error
High pressure switch has deployed.
YesYes
high-return
Alarm that indicates that high return temperature prevents the compressor's operation.
PartlyYes
high-return-line-temp
Return line temperature too high
PartlyYes
hot-water-sensor
Sensor fault alternatively cable fault (the lower sensor, Start sensor).
PartlyYes
hot-water-top
Sensor fault alternatively cable fault.
PartlyYes
low-evap-temp-1
Evaporation temperature too low.
YesYes
low-evap-temp-2
Too great a deviation in evaporation temperature average value.
YesYes
low-heat-cir-flow
The flow sensor has registered too low a flow.
YesYes
low-pressure-error
Evaporation pressure has fallen too low.
YesYes
low-pressure-transducer
Fault in low pressure transmitter alternatively cable fault.
YesYes
low-return-temp-1
The return line temperature is too low to start a defrosting.
PartlyYes
low-return-temp-2
The return line has fallen too low during defrosting.
PartlyYes
max-temp-elec-hw
Too high temperature in heat pump junction box/electrical cabinet.
Not statedYes
motor-p-comp-error
The compressor motor protection has deployed.
YesYes
motor-p-error
Deployed overload relay (overcurrent relay compressor), deployed overload relay for outdoor unit fan. On certain models alarms from the brine pump and soft starter can also occur. Compressor stopped.
YesYes
motor-p-fan-error
The fan motor protection has deployed.
YesYes
no-of-tries-x-5
Circulation pump is jammed. Start attempt made.
PartlyYes
outdoor-sensor
Sensor fault alternatively cable fault.
PartlyYes
pool-sensor
Sensor fault alternatively cable fault.
NoYes
refr-1-sensor
Sensor fault alternatively cable fault. Refrigerant sensor 1
PartlyYes
refr-2-sensor
Sensor fault alternatively cable fault. Refrigerant sensor 2
PartlyYes
return-line-sensor
Sensor fault alternatively cable fault. Return line sensor.
PartlyYes
room-sensor
Sensor fault alternatively cable fault.
NoYes
sensor-cooling
Sensor fault. Cooling function stops.
PartlyYes
suction-temp-sensor
Sensor fault alternatively cable fault.
PartlyYes
supply-line-sensor
Sensor fault alternatively cable fault. Supply line sensor.
Varies by modelYes
system-supply-line-sensor
Sensor fault alternatively cable fault. System supply line sensor.
PartlyYes