refr-1-sensor on a Thermia Atec: Sensor fault alternatively cable fault. Refrigerant sensor 1

Short answer

On a Thermia heat pump, refr-1-sensor means: Sensor fault alternatively cable fault. Refrigerant sensor 1. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Sensor fault alternatively cable fault. Refrigerant sensor 1.

Part involved: refrigerant sensor 1.

Likely causes:

  • Sensor or cable fault. (causes from the equivalent Danfoss DHP-AQ service instructions VMGFJ202).

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

What you can check

  • Note the exact alarm text. Acknowledge once (operating mode OFF then back); if it remains, contact a service technician (user manual 086L0130 p.25).

What the engineer will check

  • Disconnect the sensor and measure resistance with and without its cable against the ohm table in 'Measurement points' (section 3.3); replace the sensor if out of tolerance, otherwise the cable.

Who to ask for: heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.