no-of-tries-x-5 on a Thermia Atec: Circulation pump is jammed. Start attempt made
Short answer
On a Thermia heat pump, no-of-tries-x-5 means: Circulation pump is jammed. Start attempt made. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Circulation pump is jammed. Start attempt made.
Part involved: circulation pump.
Likely causes:
- Circulation pump jammed or air-locked; integrated shake function attempts up to 5 restarts (X = 1...5). (causes from the equivalent Danfoss DHP-AQ service instructions VMGFJ202).
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Information only |
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
What you can check
- Note the exact alarm text. Check the heating-system pressure gauge is in the range given in the user guide (Thermia/Danfoss: 1-1.5 bar when cold) - do not top up yourself unless you have been shown how; check radiator/underfloor valves and room thermostats are open. Acknowledge once (operating mode OFF then back); if it remains, contact a service technician (user manual 086L0130 p.25).
What the engineer will check
- Vent heating system and TWS coil; cut power, manually run pump; replace if recurring.
Who to ask for: heat pump engineer.
What you might notice
Sources
- Service Instructions Atec (VIIFM102) - silo.tips copy ↗ · VIIFM102 · page p.10 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.