heating-system-pump on a Thermia Atec: Circulation pump is jammed

Short answer

On a Thermia heat pump, heating-system-pump means: Circulation pump is jammed. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Circulation pump is jammed.

Part involved: heating system (secondary) circulation pump.

Likely causes:

  • Air or jammed pump. (causes from the equivalent Danfoss DHP-AQ service instructions VMGFJ202).

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Manual reset: Set operating mode OFF then back to the desired mode.

What you can check

  • Note the exact alarm text. Check the heating-system pressure gauge is in the range given in the user guide (Thermia/Danfoss: 1-1.5 bar when cold) - do not top up yourself unless you have been shown how; check radiator/underfloor valves and room thermostats are open. Acknowledge once (operating mode OFF then back); if it remains, contact a service technician (user manual 086L0130 p.25).

What the engineer will check

  • Vent system; free or replace pump.

Who to ask for: heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.