outdoor-sensor on a Thermia heat pump: Sensor fault alternatively cable fault

Short answer

On a Thermia heat pump, outdoor-sensor means: Sensor fault alternatively cable fault. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Atec

The manual says: Sensor fault alternatively cable fault.

Part involved: outdoor sensor.

Likely causes:

  • Sensor or cable fault. (causes from the equivalent Danfoss DHP-AQ service instructions VMGFJ202).

On the Diplomat

The manual says: Fault in outside sensor. When the control system calculates the heat demand, zero degrees is used.

Part involved: outdoor sensor.

On the iTec

The manual says: Something would likely have happened to the cable connection to the outdoor sensor, the cable itself or the sensor. Check for physical damages.

Part involved: outdoor sensor.

Is it safe?

On the Atec

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

On the Diplomat

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Yes, when condition clears (inferred).

On the iTec

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Manual reset: Set operating mode OFF then back.

What you can check

On the Atec

  • Note the exact alarm text. Acknowledge once (operating mode OFF then back); if it remains, contact a service technician (user manual 086L0130 p.25).

On the Diplomat

  • Note the exact alarm text. Acknowledge once by setting operating mode OFF then back; 'Other alarm message: reset the alarm; if the alarm remains, contact a service technician' (VUGFD302 p.16).

On the iTec

  • Look (without touching electrics) for visible damage to the outdoor sensor or its cable on the outside wall; acknowledge once via operating mode OFF then back; if it remains contact your installer.

What the engineer will check

On the Atec

  • Disconnect the sensor and measure resistance with and without its cable against the ohm table in 'Measurement points' (section 3.3); replace the sensor if out of tolerance, otherwise the cable.

Who to ask for: heat pump engineer.

On the Diplomat

  • Measure sensor/cable resistance (150 Ohm-type table). Causes per the equivalent Danfoss service instructions VMGFC302 (same Danfoss-era controller) - not stated in the Thermia user manual.

Who to ask for: heat pump engineer.

On the iTec

  • Measure sensor and cable resistance; repair cable or replace sensor.

Who to ask for: heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.