SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Thermia
room-sensorThermia · Atec

room-sensor on a Thermia Atec: Sensor fault alternatively cable fault

Short answer

On a Thermia heat pump, room-sensor means: Sensor fault alternatively cable fault. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Sensor fault alternatively cable fault.

Part involved: room sensor.

Likely causes:

  • Sensor or cable fault. (causes from the equivalent Danfoss DHP-AQ service instructions VMGFJ202).

Is it safe?

Does the heat pump stop?No
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running.

What you can check

  • Note the exact alarm text. Check the room sensor has not been knocked off its mounting or disconnected. Acknowledge once (operating mode OFF then back); if it remains, contact a service technician (user manual 086L0130 p.25).

What the engineer will check

  • Disconnect the sensor and measure resistance with and without its cable against the ohm table in 'Measurement points' (section 3.3); replace the sensor if out of tolerance, otherwise the cable.

Who to ask for: heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026