UH on a Mitsubishi Electric heat pump: Current sensor error or input current error

Short answer

On a Mitsubishi Electric heat pump, UH means: Current sensor error or input current error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 9 sources

What it means

On the Ecodan Hydrodan

The manual says: Current sensor error or input current error.

Part involved: Current sensor (outdoor power circuit board).

When it shows: Current sensor -1.0 A to 1.0 A during operation, or input current 40 A / 37 A for 10 s.

Likely causes:

  • 1 Disconnection of compressor wiring; 2 Defective current sensor circuit on outdoor power circuit board; 3 Decrease of power supply voltage; 4 Leakage or shortage of refrigerant.

On the Ecodan Puhz Sw Split

The manual says: Current sensor error or input current error.

Part involved: Current sensor (outdoor power circuit board).

When it shows: Current sensor -1.0 A to 1.0 A in operation (ignored in test run), or input current 40 A / 37 A for 10 s (V models).

Likely causes:

  • 1 Disconnection of compressor wiring; 2 Defective current sensor circuit on outdoor power circuit board; 3 Decrease of power supply voltage; 4 Leakage or shortage of refrigerant.

On the Ecodan Puhz W Monobloc

The manual says: Current sensor error or input current error.

Part involved: Current sensor (outdoor power circuit board).

When it shows: Current sensor reads -1.0 A to 1.0 A during compressor operation (ignored in test run), or input current above limit.

Likely causes:

  • 1 Disconnection of compressor wiring; 2 Defective current sensor circuit on outdoor power circuit board; 3 Decrease of power supply voltage; 4 Leakage or shortage of refrigerant.

On the Ecodan R290 Puz Wz

The manual says: Current sensor error or input current error.

Part involved: Current sensor (outdoor power circuit board).

When it shows: Current sensor -1.0 A to 1.0 A during operation, or input current over limit: WZ50-80V 40 A instant / 37 A for 10 s; WZ85V 38/34 A; WZ100/120V 40/37 A.

Likely causes:

  • 1 Disconnection of compressor wiring; 2 Defective current sensor circuit on outdoor power circuit board; 3 Decrease of power supply voltage; 4 Leakage or shortage of refrigerant.

On the Ecodan R32 Puz Wm

The manual says: Current sensor error or input current error.

Part involved: Current sensor (outdoor power circuit board).

When it shows: Current sensor -1.0 A to 1.0 A during compressor operation (ignored in test run), or input current 40 A (instant) / 37 A for 10 s (V models).

Likely causes:

  • 1 Disconnection of compressor wiring; 2 Defective current sensor circuit on outdoor power circuit board; 3 Decrease of power supply voltage; 4 Leakage or shortage of refrigerant.

On the Ecodan R32 Zubadan Puz Hwm

The manual says: Current sensor error or input current error.

Part involved: Current sensor (outdoor power circuit board).

When it shows: Current sensor -1.0 A to 1.0 A in operation, or input current 40 A / 39 A for 10 s (HWM140V only).

Likely causes:

  • 1 Disconnection of compressor wiring; 2 Defective current sensor circuit on outdoor power circuit board; 3 Decrease of power supply voltage; 4 Leakage or shortage of refrigerant.

On the Ecodan Ultra Quiet Puhz W Vaa

The manual says: Current sensor error or input current error.

Part involved: Current sensor (outdoor power circuit board).

When it shows: Current sensor -1.0 A to 1.0 A during operation (ignored in test run), or input current 40 A / 37 A for 10 s (W85V, W112V).

Likely causes:

  • 1 Disconnection of compressor wiring; 2 Defective current sensor circuit on outdoor power circuit board; 3 Decrease of power supply voltage; 4 Leakage or shortage of refrigerant.

On the Ecodan Zubadan Puhz Hw Monobloc

The manual says: Current sensor error or input current error.

Part involved: Current sensor (outdoor power circuit board).

When it shows: Current sensor -1.0 A to 1.0 A during operation, or input current 40 A / 37 A for 10 s (HW140V only).

Likely causes:

  • 1 Disconnection of compressor wiring; 2 Defective current sensor circuit on outdoor power circuit board; 3 Decrease of power supply voltage; 4 Leakage or shortage of refrigerant.

On the Ecodan Zubadan Puhz Shw Split

The manual says: Current sensor error or input current error.

Part involved: Current sensor (outdoor power circuit board).

When it shows: Current sensor reads -1.0 A to 1.0 A during compressor operation (ignored in test run), or input current above limit.

Likely causes:

  • 1 Disconnection of compressor wiring; 2 Defective current sensor circuit on outdoor power circuit board; 3 Decrease of power supply voltage; 4 Leakage or shortage of refrigerant.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

What you can check

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

What the engineer will check

On the Ecodan Hydrodan

  • 1 Correct compressor wiring (U-V-W); 2 Replace outdoor power circuit board; 3 Check power supply; 4 Check refrigerant leakage.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (refrigeration / F-gas).

Certification: UK F-gas Category I certification (R32, A2L mildly flammable).

On the Ecodan Puhz Sw Split

  • 1 Correct compressor wiring (U-V-W); 2 Replace outdoor power circuit board; 3 Check power supply; 4 Check refrigerant leakage.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (refrigeration / F-gas).

Certification: UK F-gas Category I certification (R410A).

On the Ecodan Puhz W Monobloc

  • 1 Correct compressor wiring (U-V-W); 2 Replace outdoor power circuit board; 3 Check power supply; 4 Check refrigerant leakage.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (refrigeration / F-gas).

Certification: UK F-gas Category I certification (R410A).

On the Ecodan R290 Puz Wz

  • 1 Correct compressor wiring (U-V-W); 2 Replace outdoor power circuit board; 3 Check power supply; 4 Check refrigerant leakage.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (refrigeration / F-gas).

Certification: UK F-gas Category I certification plus competence for flammable A3 refrigerant (R290).

On the Ecodan R32 Puz Wm

  • 1 Correct compressor wiring (U-V-W); 2 Replace outdoor power circuit board; 3 Check power supply; 4 Check refrigerant leakage.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (refrigeration / F-gas).

Certification: UK F-gas Category I certification (R32, A2L mildly flammable).

On the Ecodan R32 Zubadan Puz Hwm

  • 1 Correct compressor wiring (U-V-W); 2 Replace outdoor power circuit board; 3 Check power supply; 4 Check refrigerant leakage.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (refrigeration / F-gas).

Certification: UK F-gas Category I certification (R32, A2L mildly flammable).

On the Ecodan Ultra Quiet Puhz W Vaa

  • 1 Correct compressor wiring (U-V-W); 2 Replace outdoor power circuit board; 3 Check power supply; 4 Check refrigerant leakage.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (refrigeration / F-gas).

Certification: UK F-gas Category I certification (R410A).

On the Ecodan Zubadan Puhz Hw Monobloc

  • 1 Correct compressor wiring (U-V-W); 2 Replace outdoor power circuit board; 3 Check power supply; 4 Check refrigerant leakage.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (refrigeration / F-gas).

Certification: UK F-gas Category I certification (R410A).

On the Ecodan Zubadan Puhz Shw Split

  • 1 Correct compressor wiring (U-V-W); 2 Replace outdoor power circuit board; 3 Check power supply; 4 Check refrigerant leakage.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (refrigeration / F-gas).

Certification: UK F-gas Category I certification (R410A).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026