Heat pumps · Error codes · Mitsubishi Electric
P1Mitsubishi Electric

P1 on a Mitsubishi Electric heat pump: Flow water (TH1) sensor error

Short answer

On a Mitsubishi Electric heat pump, P1 means: Flow water (TH1) sensor error. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 9 sources

What it means

On the Ecodan

The manuals for this range word it in different ways:

  • Flow water (TH1) sensor error.
  • Thermistor (Flow water temp.) (THW1) failure.
  • Thermistor (Room temp.) (TH1) failure (TH1A/TH1B room temperature thermistor).

Part involved: Flow water thermistor TH1; Flow water thermistor THW1; Room temperature thermistor TH1 (in main remote controller / wireless remote controller / room sensor).

When it shows: Thermistor open (-39C or below) or short (88.5C or above).

Likely causes:

  • Thermistor open/short or disconnected; FTC board fault.
  • 1 Connector/terminal wire detached or loose; 2 Thermistor fault; 3 FTC board failure; 4 Thermistor in the wireless or main remote controller defective (when room temperature control uses main RC or Room RC 1-8); 5 Incorrect DIP switch setting.

On the Ecodan Co2 Quhz

The manual says: Indoor unit temperature thermistor (room temp. TH1) failure.

Part involved: Room thermistor TH1A/TH1B.

When it shows: Thermistor open or short.

Likely causes:

  • Connector detached; thermistor fault; FTC board failure; wireless/main remote controller thermistor defective.

On the Ecodan Hydrodan

The manual says: Thermistor (Room temp.) (TH1) failure (TH1A/TH1B room temperature thermistor).

Part involved: Room temperature thermistor TH1 (in main remote controller / wireless remote controller / room sensor).

When it shows: Thermistor open (-39C or below) or short (88.5C or above).

Likely causes:

  • 1 Connector/terminal wire detached or loose; 2 Thermistor fault; 3 FTC board failure; 4 Thermistor in the wireless or main remote controller defective (when room temperature control uses main RC or Room RC 1-8); 5 Incorrect DIP switch setting.

Is it safe?

On the Ecodan

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated as auto-resetting; code remains until reset.

Manual reset: Installation manuals: press F4 (RESET) then F3 (Yes) on the main remote controller (older controllers: hold button E for 3 s); 'To cancel error codes please switch system off'. Fix the cause first.

On the Ecodan Co2 Quhz

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated as auto-recovering.

Manual reset: Press F4 (Reset) then F3 (Yes) on the main remote controller, or switch system off (installation manual).

On the Ecodan Hydrodan

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated as auto-resetting; code remains until reset.

Manual reset: Installation manuals: press F4 (RESET) then F3 (Yes) on the main remote controller (older controllers: hold button E for 3 s); 'To cancel error codes please switch system off'. Fix the cause first.

What you can check

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer (Mitsubishi user manuals: 'Make a note of the error code number and contact installer'). Check the heat pump breaker/isolator at the consumer unit is on and read the primary system pressure gauge (if fitted) so you can report it. A single reset from the main remote controller (RESET, then Yes) may be tried; if the code returns, do not keep resetting. Do not open the outdoor unit, cylinder/hydrobox or any casing.

What the engineer will check

On the Ecodan

  • Check resistance across the thermistor; check connections.
  • 1 Check connections; 2 Check thermistor resistance; 3 Replace board; 4 Replace wireless or main remote controller; 5 Check DIP switches / room sensor settings.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (controls / wiring).

On the Ecodan Co2 Quhz

  • Check connections and resistance; replace board or remote controller; check room sensor settings.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (controls / wiring).

On the Ecodan Hydrodan

  • 1 Check connections; 2 Check thermistor resistance; 3 Replace board; 4 Replace wireless or main remote controller; 5 Check DIP switches / room sensor settings.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (controls / wiring).

What you might notice

What owners and engineers report

23 owner and engineer reports mention this.

  • Controller / thermostat problem on the Ecodan: 14 reports
  • No heating on the Ecodan: 9 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026