Heat pumps · Error codes · Mitsubishi Electric
LLMitsubishi Electric

LL on a Mitsubishi Electric heat pump: Setting errors of DIP switches on FTC4 control board (boiler, 2-zone, multiple outdoor units)

Short answer

On a Mitsubishi Electric heat pump, LL means: Setting errors of DIP switches on FTC4 control board (boiler, 2-zone, multiple outdoor units). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 5 sources

What it means

On the Ecodan

The manuals for this range word it in different ways:

  • Setting errors of DIP switches on FTC4 control board (boiler, 2-zone, multiple outdoor units).
  • Setting errors of DIP switches on FTC control board (boiler / 2-zone).

Part involved: FTC DIP switches.

When it shows: Incompatible DIP switch combination detected.

Likely causes:

  • Incorrect setting of DIP switches (commissioning error).

On the Ecodan Hydrodan

The manual says: Setting errors of DIP switches on FTC control board (boiler / 2-zone).

Part involved: FTC DIP switches.

When it shows: Incompatible DIP switch combination detected.

Likely causes:

  • Incorrect setting of DIP switches (commissioning error).

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-resetting; code remains until reset.

Manual reset: Installation manuals: press F4 (RESET) then F3 (Yes) on the main remote controller (older controllers: hold button E for 3 s); 'To cancel error codes please switch system off'. Fix the cause first.

What you can check

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer (Mitsubishi user manuals: 'Make a note of the error code number and contact installer'). Check the heat pump breaker/isolator at the consumer unit is on and read the primary system pressure gauge (if fitted) so you can report it. A single reset from the main remote controller (RESET, then Yes) may be tried; if the code returns, do not keep resetting. Do not open the outdoor unit, cylinder/hydrobox or any casing.

What the engineer will check

On the Ecodan

  • Boiler: DIP SW1-1 ON (with boiler) and SW2-6 ON (with mixing tank); 2-zone: SW2-7 ON and SW2-6 ON; multiple outdoor units control: SW1-3 ON on the slave unit that runs DHW.
  • Boiler: DIP SW1-1 ON (with boiler) and SW2-6 ON (with mixing tank); 2-zone: SW2-7 ON (2-zone) and SW2-6 ON (with mixing tank).

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (controls / wiring).

On the Ecodan Hydrodan

  • Boiler: DIP SW1-1 ON (with boiler) and SW2-6 ON (with mixing tank); 2-zone: SW2-7 ON (2-zone) and SW2-6 ON (with mixing tank).

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (controls / wiring).

What you might notice

What owners and engineers report

2 owner and engineer reports mention this.

  • Heat pump will not start on the Ecodan: 2 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026