Heat pumps · Error codes · Mitsubishi Electric
LDMitsubishi Electric

LD on a Mitsubishi Electric heat pump: Boiler temperature thermistor (THWB1, THWB2) failure

Short answer

On a Mitsubishi Electric heat pump, LD means: Boiler temperature thermistor (THWB1, THWB2) failure. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 5 sources

What it means

On the Ecodan

The manuals for this range word it in different ways:

  • Boiler temperature thermistor (THWB1, THWB2) failure.
  • Boiler temperature thermistor (THWB1) failure (FTC7: Thermistor (Boiler flow water temp.) (THWB1)).

Part involved: Boiler thermistors THWB1, THWB2; Boiler flow thermistor THWB1.

When it shows: THWB1/THWB2 open (-40C or below) or short (140C or above) THWB1 open (-40C or below) or short (140C or above).

Likely causes:

  • 1 Connector/terminal detached or loose; 2 Thermistor fault; 3 FTC board failure.

On the Ecodan Hydrodan

The manual says: Boiler temperature thermistor (THWB1) failure (FTC7: Thermistor (Boiler flow water temp.) (THWB1)).

Part involved: Boiler flow thermistor THWB1.

When it shows: THWB1 open (-40C or below) or short (140C or above).

Likely causes:

  • 1 Connector/terminal detached or loose; 2 Thermistor fault; 3 FTC board failure.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated as auto-resetting; code remains until reset.

Manual reset: Installation manuals: press F4 (RESET) then F3 (Yes) on the main remote controller (older controllers: hold button E for 3 s); 'To cancel error codes please switch system off'. Fix the cause first.

What you can check

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer (Mitsubishi user manuals: 'Make a note of the error code number and contact installer'). Check the heat pump breaker/isolator at the consumer unit is on and read the primary system pressure gauge (if fitted) so you can report it. A single reset from the main remote controller (RESET, then Yes) may be tried; if the code returns, do not keep resetting. Do not open the outdoor unit, cylinder/hydrobox or any casing.

What the engineer will check

  • Check resistance across the thermistor; check connections; replace board if needed.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (controls / wiring).

What you might notice

What owners and engineers report

9 owner and engineer reports mention this.

  • No heating on the Ecodan: 9 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026