UF on a Mitsubishi Electric heat pump: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start

Short answer

On a Mitsubishi Electric heat pump, UF means: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 9 sources

What it means

On the Ecodan Hydrodan

The manual says: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start.

Part involved: Compressor / outdoor power circuit board.

When it shows: Overcurrent of DC bus or compressor within 30 s after compressor starts.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Looseness, disconnection or reverse of compressor wiring; 3 Defective compressor; 4 Defective outdoor power board.

On the Ecodan Puhz Sw Split

The manual says: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start.

Part involved: Compressor / outdoor power circuit board.

When it shows: Overcurrent of DC bus or compressor within 30 s after compressor starts.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Looseness, disconnection or reverse of compressor wiring; 3 Defective compressor; 4 Defective outdoor power board.

On the Ecodan Puhz W Monobloc

The manual says: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start.

Part involved: Compressor / outdoor power circuit board.

When it shows: Overcurrent of DC bus or compressor within 30 s after compressor starts.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Compressor wiring loose/disconnected/reversed; 3 Defective compressor; 4 Defective outdoor power board; 5 Decreased water flow; 6 Clogged water filter; 7 Clogged plate heat exchanger; 8 Locked water pump; 9 Malfunction of water pump.

On the Ecodan R290 Puz Wz

The manual says: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start.

Part involved: Compressor / outdoor power circuit board.

When it shows: Overcurrent of DC bus or compressor within 30 s after compressor starts.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Compressor wiring loose/disconnected/reversed; 3 Defective compressor; 4 Defective outdoor power board; 5 DIP switch setting difference on outdoor controller board.

On the Ecodan R32 Puz Wm

The manual says: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start.

Part involved: Compressor / outdoor power circuit board.

When it shows: Overcurrent of DC bus or compressor within 30 s after compressor starts.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Looseness, disconnection or reverse of compressor wiring; 3 Defective compressor; 4 Defective outdoor power board.

On the Ecodan R32 Zubadan Puz Hwm

The manual says: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start.

Part involved: Compressor / outdoor power circuit board.

When it shows: Overcurrent of DC bus or compressor within 30 s after compressor starts.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Compressor wiring loose/disconnected/reversed; 3 Defective compressor; 4 Defective outdoor power board; 5 Decreased water flow; 6 Clogged water filter; 7 Clogged plate heat exchanger; 8 Locked water pump; 9 Malfunction of water pump.

On the Ecodan Ultra Quiet Puhz W Vaa

The manual says: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start.

Part involved: Compressor / outdoor power circuit board.

When it shows: Overcurrent of DC bus or compressor within 30 s after compressor starts.

Likely causes:

  • 1 Stop valve closed; 2 Decrease of power supply voltage; 3 Compressor wiring loose/disconnected/reversed; 4 Defective compressor; 5 Defective outdoor power board.

On the Ecodan Zubadan Puhz Hw Monobloc

The manual says: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start.

Part involved: Compressor / outdoor power circuit board.

When it shows: Overcurrent of DC bus or compressor within 30 s after compressor starts.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Compressor wiring loose/disconnected/reversed; 3 Defective compressor; 4 Defective outdoor power board; 5 Decreased water flow; 6 Clogged water filter; 7 Clogged plate heat exchanger; 8 Locked water pump; 9 Malfunction of water pump.

On the Ecodan Zubadan Puhz Shw Split

The manual says: Compressor overcurrent interruption (when compressor locked): overcurrent within 30 seconds of compressor start.

Part involved: Compressor / outdoor power circuit board.

When it shows: Overcurrent of DC bus or compressor within 30 s after compressor starts.

Likely causes:

  • 1 Decrease of power supply voltage; 2 Looseness, disconnection or reverse of compressor wiring; 3 Defective compressor; 4 Defective outdoor power board.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

What you can check

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer. Do not reset repeatedly: this is an electrical/compressor protection code. If the breaker or RCD has tripped, or there is a burning smell, leave the heat pump switched off at its isolator and call an engineer. Do not open any casing.

What the engineer will check

On the Ecodan Hydrodan

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check compressor; 4 Replace outdoor power circuit board.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R32, A2L mildly flammable).

On the Ecodan Puhz Sw Split

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check compressor; 4 Replace outdoor power circuit board.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R410A).

On the Ecodan Puhz W Monobloc

  • 1 Check power supply; 2 Correct compressor wiring; 3 Check compressor; 4 Replace power board; 5-9 Check water circuit and repair.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R410A).

On the Ecodan R290 Puz Wz

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check compressor; 4 Replace outdoor power circuit board.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification plus competence for flammable A3 refrigerant (R290).

On the Ecodan R32 Puz Wm

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check compressor; 4 Replace outdoor power circuit board.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R32, A2L mildly flammable).

On the Ecodan R32 Zubadan Puz Hwm

  • 1 Check power supply; 2 Correct compressor wiring; 3 Check compressor; 4 Replace power board; 5-9 Check water circuit and repair.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R32, A2L mildly flammable).

On the Ecodan Ultra Quiet Puhz W Vaa

  • 1 Open stop valve; 2 Check power supply; 3 Correct compressor wiring (U-V-W); 4 Check compressor; 5 Replace outdoor power board.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R410A).

On the Ecodan Zubadan Puhz Hw Monobloc

  • 1 Check power supply; 2 Correct compressor wiring; 3 Check compressor; 4 Replace power board; 5-9 Check water circuit and repair.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R410A).

On the Ecodan Zubadan Puhz Shw Split

  • 1 Check power supply; 2 Correct compressor wiring (U-V-W); 3 Check compressor; 4 Replace outdoor power circuit board.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (electrical / inverter diagnostics).

Certification: Competent electrician (BS 7671 / Part P); heat pump inverter experience; UK F-gas Category I certification (R410A).

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • Heat pump will not start on the Ecodan Puhz W Monobloc: 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026