Heat pumps · Error codes · Mitsubishi Electric
UEMitsubishi Electric

UE on a Mitsubishi Electric heat pump: Abnormal pressure of pressure sensor 63HS (63HS detects 0.1 MPa or less)

Short answer

On a Mitsubishi Electric heat pump, UE means: Abnormal pressure of pressure sensor 63HS (63HS detects 0.1 MPa or less). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 9 sources

What it means

The manual says: Abnormal pressure of pressure sensor 63HS (63HS detects 0.1 MPa or less).

Part involved: Pressure sensor 63HS.

When it shows: 63HS <= 0.1 MPa (inoperative 3 min after compressor start and during/3 min after defrost).

Likely causes:

  • 1 Disconnection or contact failure of 63HS connector on outdoor controller board; 2 Defective pressure sensor; 3 Defective outdoor controller board.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

What you can check

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer (Mitsubishi user manuals: 'Make a note of the error code number and contact installer'). Check the heat pump breaker/isolator at the consumer unit is on and read the primary system pressure gauge (if fitted) so you can report it. A single reset from the main remote controller (RESET, then Yes) may be tried; if the code returns, do not keep resetting. Do not open the outdoor unit, cylinder/hydrobox or any casing.

What the engineer will check

  • 1 Check 63HS connector and lead wire; 2 Check pressure via microprocessor (SW2); 3 Replace outdoor controller board.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (controls / wiring).

What you might notice