Heat pumps · Error codes · MasterTherm
AL13MasterTherm

AL13 on a MasterTherm heat pump: DC Drive Alarm - alarm of the compressor inverter drive (inverter units only)

Short answer

On a MasterTherm heat pump, AL13 means: DC Drive Alarm - alarm of the compressor inverter drive (inverter units only). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 1 source

What it means

On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)

The manual says: DC Drive Alarm - alarm of the compressor inverter drive (inverter units only).

Part involved: DC drive (inverter).

When it shows: Control action: Switches off compressor and fan. Operator guidance: Turn power off and on; if the problem persists contact the installer.

Likely causes:

  • DC drive malfunction.
  • Pressure transducer malfunction (per air/water table).

On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)

The manual says: DC Drive Alarm (inverter units only).

Part involved: DC drive.

When it shows: Control action: Switches off compressor and brine circulator. Operator guidance: Restart unit power supply; if problem returns call service.

Likely causes:

  • Compressor DC drive error.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Automatic.

Manual reset: After 3 occurrences in 1 compressor operating hour the unit is blocked (ALARM key lit steadily); manual reset by pressing ALARM key on the alarm display (pGD) or RESET on pGDx Alarm Management.

What you can check

On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)

  • Read and note the alarm (ALx code/text) and the alarm counter shown on the pGD/pGDx display.
  • Check the heat pump breaker/isolator in the consumer unit is on.
  • Power-cycle the heat pump once at its consumer-unit breaker/isolator as the manual allows.

On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)

  • Read and note the alarm (ALx code/text) and the alarm counter shown on the pGD/pGDx display.
  • Check the heat pump breaker/isolator in the consumer unit is on.
  • Power-cycle the heat pump once at its breaker/isolator.

What the engineer will check

On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)

  • Read detailed DC drive alarm (PRG key in alarm menu).
  • Check drive, transducer, supply.

Who to ask for: heat pump service engineer (refrigeration/controls).

Certification: F-gas certification (refrigerant circuit work); electrical competence for switchboard work.

On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)

  • Read detailed DC drive alarm (PRG).
  • Check drive.

Who to ask for: ground source heat pump engineer (refrigeration/controls).

Certification: F-gas certification (refrigerant circuit work); electrical competence for switchboard work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026