AL04MasterTherm

AL04 on a MasterTherm heat pump: High Condensing Temperature in heating/cooling mode

Short answer

On a MasterTherm heat pump, AL04 means: High Condensing Temperature in heating/cooling mode. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)

The manual says: High Condensing Temperature in heating/cooling mode.

Part involved: condenser / fan (cooling) / defrost end setting.

When it shows: Control action: Switches off compressor and fan. Operator guidance: Check the outdoor unit and perform a manual reset; installation company must be contacted.

Likely causes:

  • Defrost end temperature set too high (thawing mode).
  • Fan failure in cooling mode.

On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)

The manual says: High Condensing Temperature in heating/cooling mode.

Part involved: condenser.

When it shows: Control action: Switches off compressor and brine circulator. Operator guidance: Decrease requested water temperature, check deaeration and filling, clean strainers; repeated - call service.

Likely causes:

  • Too high water/brine temperature.
  • Full water/brine strainer.
  • Water/brine circulator malfunction.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Resets automatically after the minimum compressor off time (~6 min) if the same alarm occurs fewer than 3 times per compressor operating hour.

Manual reset: After 3 occurrences in 1 compressor operating hour the unit is blocked (ALARM key lit steadily); manual reset by pressing ALARM key on the alarm display (pGD) or RESET on pGDx Alarm Management.

What you can check

On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)

  • Read and note the alarm (ALx code/text) and the alarm counter shown on the pGD/pGDx display.
  • Check the heat pump breaker/isolator in the consumer unit is on.
  • Check the outdoor unit is not blocked (airflow).
  • Manual reset via ALARM key as described in the manual, then contact the installer.

On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)

  • Read and note the alarm (ALx code/text) and the alarm counter shown on the pGD/pGDx display.
  • Check the heat pump breaker/isolator in the consumer unit is on.
  • Reduce the requested heating water temperature.

What the engineer will check

On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)

  • Check defrost end parameters.
  • Check fan and fan circuit breaker.

Who to ask for: heat pump service engineer (refrigeration/controls).

Certification: F-gas certification (refrigerant circuit work); electrical competence for switchboard work.

On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)

  • Clean water/brine strainers.
  • Check circulators.

Who to ask for: ground source heat pump engineer (refrigeration/controls).

Certification: F-gas certification (refrigerant circuit work); electrical competence for switchboard work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026