AL07 on a MasterTherm heat pump: Fan Thermal - fan overheating or fan circuit breaker activation
Short answer
On a MasterTherm heat pump, AL07 means: Fan Thermal - fan overheating or fan circuit breaker activation. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.
Reviewed 23 September 2026 · 1 source
What it means
On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)
The manual says: Fan Thermal - fan overheating or fan circuit breaker activation.
Part involved: outdoor fan motor / fan circuit breaker.
When it shows: Control action: Switches off compressor and fan. Operator guidance: Check the outdoor unit and perform a reset; call service.
Likely causes:
- Fan overloading.
- Faulty fan.
On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)
The manual says: Brine pump malfunction - brine circulator overheating or circuit breaker activation (larger units only).
Part involved: brine circulation pump.
When it shows: Control action: Switches off compressor and brine circulator. Operator guidance: Call service.
Likely causes:
- Brine circulator motor overheating.
- Circuit breaker activation.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — clears by itself when the condition goes |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: Resets automatically after the minimum compressor off time (~6 min) if the same alarm occurs fewer than 3 times per compressor operating hour.
Manual reset: After 3 occurrences in 1 compressor operating hour the unit is blocked (ALARM key lit steadily); manual reset by pressing ALARM key on the alarm display (pGD) or RESET on pGDx Alarm Management.
What you can check
On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)
- Read and note the alarm (ALx code/text) and the alarm counter shown on the pGD/pGDx display.
- Check the heat pump breaker/isolator in the consumer unit is on.
- Check the outdoor unit fan is not obstructed by debris/snow (do not touch the fan).
On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)
- Read and note the alarm (ALx code/text) and the alarm counter shown on the pGD/pGDx display.
- Check the heat pump breaker/isolator in the consumer unit is on.
What the engineer will check
On the pCO5/pGD controller alarms - air/water units (BoxAir, BoxAir Inverter, BoxAir Inverter P, AirMaster, EasyMaster)
- Check fan motor windings, thermal protection and circuit breaker in switchboard.
Who to ask for: heat pump service engineer (refrigeration/controls).
Certification: F-gas certification (refrigerant circuit work); electrical competence for switchboard work.
On the pCO5/pGD controller alarms - brine/water and water/water units (AquaMaster, AquaMaster Inverter, Inverter P, Combi)
- Check brine pump motor and its circuit breaker.
Who to ask for: ground source heat pump engineer (refrigeration/controls).
Certification: F-gas certification (refrigerant circuit work); electrical competence for switchboard work.
What you might notice
Sources
- MasterTherm pCO5/pGD digital controller - OEM instruction manual, heat pumps AirMaster, AquaMaster, EasyMaster, BoxAir (Documentation PGD1-MANUAL, Edition 41, sw_11) ↗ · Edition 41 / sw_11 · pages 31, 42-43, 31, 40-41 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026